
Thermo Fisher Scientific CX3CR1 Monoclonal Antibody (2A9-1), PerCP-eFluor 710, eBioscience
CX3CR1 단백질을 표적하는 2A9-1 클론의 Rat 모노클론 항체로, PerCP-eFluor 710 형광체가 결합된 제품. 인간 및 마우스 시료에 반응하며 Flow Cytometry 분석에 최적화됨. 488 nm 청색 레이저로 여기되며 710 nm에서 방출. 연구용으로 사용 권장.
- 카탈로그번호
- 46-6099-42
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CX3CR1 Monoclonal Antibody (2A9-1), PerCP-eFluor 710, eBioscience
Thermo Fisher Scientific CX3CR1 Monoclonal Antibody (2A9-1), PerCP-eFluor 710, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.25 µg)/test
Publications: View 5 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Published Species | Human, Mouse |
| Host / Isotype | Rat / IgG2b, kappa |
| Recommended Isotype Control | Rat IgG2b kappa Isotype Control (eB149/10H5), PerCP-eFluor™ 710 |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 2A9-1 |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation / Emission Max | 482 / 708 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with 0.2% BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_10717390 |
Additional Formats
- Alexa Fluor 488
- APC
- Biotin
- PE
- PE-Cyanine7
- PE-eFluor 610
- Super Bright 702
- Request custom conjugation available
Product Specific Information
This 2A9-1 monoclonal antibody reacts with human CX3CR1, the receptor for fractalkine, a transmembrane chemokine of the CX3C family. CX3CR1 is a seven transmembrane G protein-coupled receptor expressed on CD16+ NK cells, T cells (CD8+, CD4+, γ/δ), and monocytes. It is also found on osteoclast precursors and microglia, but shows little to no expression on B cells and granulocytes.
Fractalkine and CX3CR1 mediate cell-cell adhesion and chemotaxis of NK cells, T cells, and monocytes. Expression correlates with high levels of intracellular perforin and granzyme B.
Applications Reported: Flow cytometric analysis.
Applications Tested: Pre-titrated and tested by flow cytometry of normal human peripheral blood cells. Recommended usage: 5 µL (0.25 µg)/test (in 100 µL final volume). Cell number range: 10⁵–10⁸ cells/test.
PerCP-eFluor® 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5. It emits at 710 nm and is excited at 488 nm (blue laser). Recommended filters: 685 LP dichroic mirror with 710/40 band pass (695/40 acceptable alternative).
PerCP-eFluor® 710 conjugated antibodies are stable when samples are fixed with freshly prepared 2% formaldehyde overnight at 4°C.
Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
CX3CR1 is a chemokine receptor acting as a coreceptor for HIV infection. Human, mouse, and rat CX3CR1 genes (V28, CMKBRL1, RBS11) encode a seven transmembrane protein identified as the receptor for fractalkine. CX3CR1 mediates leukocyte migration and adhesion, and is expressed in various human tissues and cell lines.
For Research Use Only. Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.

