CacheBy
Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience
원본

Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience

상품 한눈에 보기

인간 HLA-A3 항원을 인식하는 GAP.A3 단클론 항체로, NovaFluor Blue 690 형광체로 결합되어 있습니다. Flow cytometry에 최적화되어 있으며 CellBlox Plus Blocking Buffer와 함께 사용 시 최적의 형광 신호를 제공합니다. 연구용으로만 사용됩니다.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
ADBIX 2026 전시회10/28~30 코엑스 · 사전등록 안내자세히보기
Thermo Fisher Scientific H071T03B09-A HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience 100 tests pk판매 단위 pk
재고 확인 필요
653,000원VAT 포함 718,300원
Thermo Fisher Scientific H071T02B09-A HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience 25 tests pk판매 단위 pk
재고 확인 필요
306,000원VAT 포함 336,600원

Thermo Fisher Scientific · Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience

Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 690, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 5 µL (0.6 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host/Isotype Mouse / IgG2a, kappa
Class Monoclonal
Type Antibody
Clone GAP.A3
Conjugate NovaFluor™ Blue 690
Excitation/Emission Max 672/688 nm
Form Liquid
Concentration 0.6 µg/Test
Purification Affinity chromatography
Storage buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3098780 (AB_2937273)

Additional Formats

  • APC
  • FITC
  • NovaFluor Blue 510
  • NovaFluor Blue 585
  • NovaFluor Blue 610-70S
  • NovaFluor Blue 660-120S
  • NovaFluor Red 710
  • NovaFluor Red 725
  • NovaFluor Yellow 570
  • NovaFluor Yellow 660
  • NovaFluor Yellow 730
  • NovaFluor Yellow 755
  • PE
  • Super Bright 436
  • Super Bright 600
  • Request custom conjugation

Product Specific Information

The monoclonal antibody GAP.A3 reacts with the human major histocompatibility complex (MHC) class I molecule HLA-A3, a member of the HLA-A family.
HLA-A3 exists as two subtypes (HLA-A3.1 and HLA-A3.2) differing at amino acid positions 152 and 156.
MHC class I molecules are expressed on all nucleated cells and present intracellular peptides to cytotoxic T lymphocytes.
HLA-A3 is expressed by 15–25% of cancer patients and binds the tumor-associated antigen human telomerase reverse transcriptase (hTERT).

Each product contains:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells.
Recommended use: 5 µL (0.6 µg) per test in 100 µL final volume (10⁵–10⁸ cells/test).

Compatibility Notice:
NovaFluor dyes are not compatible with DNA intercalating viability dyes such as propidium iodide, 7-AAD, and DAPI.
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for NovaFluor dyes.

CellBlox Plus Blocking Buffer Usage:
Use 5 µL per sample (regardless of NovaFluor count) for antibody cocktails.
For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).

NovaFluor conjugates utilize Phiton™ technology, engineered for optimized fluorescent signatures minimizing spillover and spread.
Excitation: 494 nm; Emission: 585 nm; Laser: 488 nm (Blue).

Target Information

HLA-A belongs to the HLA class I heavy chain paralogues. It is a heterodimer of a heavy chain and β2-microglobulin.
Class I molecules present peptides derived from the endoplasmic reticulum lumen and are expressed in nearly all cells.
The heavy chain (~45 kDa) gene contains 8 exons:

  • Exon 1: leader peptide
  • Exons 2–3: α1 and α2 domains (peptide binding)
  • Exon 4: α3 domain
  • Exon 5: transmembrane region
  • Exons 6–7: cytoplasmic tail

Polymorphisms within exons 2 and 3 determine peptide binding specificity.
Typing of these polymorphisms is routinely performed for bone marrow and kidney transplantation.
Hundreds of HLA-A alleles have been described.

HLA and MHC antibodies are key tools in Immunopeptidomics, aiding neoantigen identification via LC-MS/MS.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0개

아직 등록된 문의가 없어요.