Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), Alexa Fluor 532, eBioscience
Armenian hamster 유래 IgG 동형 대조항체로, Alexa Fluor 532로 표지되어 있습니다. Flow cytometry용으로 검증되었으며, 비특이적 결합을 구분하기 위한 음성 대조로 사용됩니다. Green laser(532 nm)에서 여기되어 561 nm에서 방출합니다. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- 58-4888-80
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Armenian Hamster IgG Isotype Control (eBio299Arm), Alexa Fluor 532, eBioscience
Applications
- Flow Cytometry (Flow): Assay-dependent
- Control (Ctrl): Assay-dependent
Product Specifications
| 항목 | 내용 |
|---|---|
| Host / Isotype | Armenian hamster / IgG |
| Class | Monoclonal |
| Type | Isotype Control |
| Clone | eBio299Arm |
| Conjugate | Alexa Fluor™ 532 |
| Excitation / Emission Max | 534 / 553 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| Shipping conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_11220475 |
Available Formats
- Unconjugated
- Alexa Fluor 488
- Alexa Fluor 660
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV / Violet series (395–805)
- eFluor 450 / 506 / 615 / 660
- FITC
- Functional Grade
- PE and PE tandem dyes (PE-Cyanine5, PE-Cyanine7, etc.)
- PerCP-Cyanine5.5, PerCP-eFluor 710
- Super Bright series (436–780)
- Custom conjugation available upon request
Product Specific Information
The eBio299Arm monoclonal antibody serves as an isotype control immunoglobulin.
- Applications Reported: Flow cytometric analysis
- Applications Tested: Tested on mouse splenocytes and human peripheral blood cells
- Usage: Should be used at the same concentration as the experimental antibody
Fluorophore Information:
Alexa Fluor® 532 is excited with the Green laser (532 nm) and emits at 561 nm.
This dye is not compatible with the Yellow-Green laser (561 nm).
Recommended filter: 560/14 band pass filter.
Ensure your instrument supports detection of this fluorochrome.
- Excitation: 532 nm
- Emission: 561 nm
- Laser: Green laser
Target Information
Isotype control antibodies help distinguish non-specific background signal from specific antibody signal.
They are particularly useful in flow cytometry, but also applicable in other assays such as:
- Chromatin immunoprecipitation (ChIP)
- Immunohistochemistry
- Gel shift assays
Isotype controls should match the species and isotype of the primary antibody and, if directly labeled, use the same fluorophore for accurate comparison.
For Research Use Only.
Not for use in diagnostic procedures.
Not for resale without express authorization.