Thermo Fisher Scientific LIVE/DEAD Fixable Red Dead Cell Stain Kit, for 488 nm excitation, 200 Assays
세포 생존 여부를 고정 전 판별하는 형광 염색 키트로, 488 nm 여기에서 작동하며 고정 후에도 일관된 신호를 유지합니다. 강한 형광 신호로 단일 채널에서 생세포와 사세포를 명확히 구분할 수 있어 다중 컬러 유세포 분석에 최적입니다.
- 판매단위
- pk
카탈로그
3개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific LIVE/DEAD Fixable Red Dead Cell Stain Kit, for 488 nm excitation, 200 Assays
Invitrogen™ LIVE/DEAD™ Fixable Red Dead Cell Stain Kit, for 488 nm excitation
The LIVE/DEAD™ Fixable Red Dead Cell Stain Kit is used to determine the viability of cells prior to fixation and permeabilization required for intracellular antibody staining, or before elimination of biohazardous materials using formaldehyde fixation. This kit is optimized and validated for use with a blue laser flow cytometer.
주요 특징
- Stable — Dyes are freeze-dried in separate vials to maintain stability.
- Robust — Staining pattern remains consistent before and after fixation.
- Bright Signal — Enables clear distinction between live and dead cells using a single channel.
Selection guide for all fixable viability dyes for flow cytometry
Stable
Unlike products sold in solution, the LIVE/DEAD™ Fixable Red Stain is packaged in 40-test vials to ensure dye stability and performance over time. Amine-reactive dyes in solution lose effectiveness quickly, so use the vial completely once rehydrated. If partial use is necessary, aliquot and store at −80°C, avoiding freeze-thaw cycles.
Robust
Dead cell discriminator stains can lose sensitivity after fixation with formaldehyde or ethanol. The LIVE/DEAD™ Fixable Red Stain binds covalently to intracellular and extracellular amines, preserving staining patterns after formaldehyde fixation.
Optimal Brightness
The red-fluorescent reactive dye provides a bright signal when excited by yellow, green, or blue (488 nm) lasers.
- Excitation maximum: ~595 nm
- Emission maximum: ~615 nm
Ideal for single-channel discrimination of live/dead cells and multi-color flow cytometry experiments.
How It Works
- Dead cells: Dye reacts with free amines inside and on the surface, yielding intense fluorescence.
- Live cells: Reactivity limited to surface amines, resulting in weaker fluorescence.
The fluorescence intensity difference (>50-fold) allows easy discrimination of live and dead cells.
Colors Available
LIVE/DEAD™ Fixable Dead Cell Stains are available in multiple colors to suit diverse multi-color panel needs.
제품 사양
| 항목 | 내용 |
|---|---|
| 세포 투과성 | Impermeant |
| 세포 유형 | Eukaryotic Cells |
| 색상 | Red |
| 설명 | LIVE/DEAD™ Fixable Red Dead Cell Stain Kit, for 488 nm excitation |
| 검출 방법 | Fluorescence |
| 용도(애플리케이션) | Viability Assay |
| 용도 (장비) | Flow Cytometer |
| 제품 유형 | Stain |
| 염료 유형 | LIVE/DEAD™ Fixable Red Dead Cell Stain |
| 방출 | 615 nm |
| 여기 파장 범위 | 488, 595 nm |
| 형태 | Solid |
| 형식 | Tube(s) |
| 제품라인 | LIVE/DEAD™ |
| 수량 | 200 Assays |
| 배송 조건 | Room Temperature |
| 용해도 | DMSO (Dimethylsulfoxide) |
| Unit Size | Each |
Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.