Thermo Fisher Scientific CD8b Monoclonal Antibody (SIDI8BEE), NovaFluor Blue 610-70S, eBioscience
인간 및 비인간 영장류 CD8β 검출용 단클론 항체로, NovaFluor Blue 610-70S 형광체 결합. Flow Cytometry에 최적화되어 있으며 CellBlox Plus Blocking Buffer 포함. 492/616 nm 발광 특성, 4°C 암저장. 연구용 전용 제품.
- 카탈로그번호
- H057T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD8b Monoclonal Antibody (SIDI8BEE), NovaFluor Blue 610-70S, eBioscience
Thermo Fisher Scientific CD8b Monoclonal Antibody (SIDI8BEE), NovaFluor Blue 610-70S, eBioscience
Applications
- Reported: Flow Cytometry
- Tested: Flow Cytometry (5 µL, 0.8 µg/test)
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human, Non-human primate |
| Host/Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | SIDI8BEE |
| Conjugate | NovaFluor™ Blue 610-70S |
| Excitation/Emission Max | 492 / 616 nm |
| Form | Liquid |
| Concentration | 0.8 µg/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098668 (AB_2926051) |
Additional Formats
- Unconjugated
- Brilliant UV 661
- Brilliant Violet 605
- eFluor 660
- NovaFluor Blue 510 / 585 / 690
- NovaFluor Red 725 / 755
- NovaFluor Yellow 755
- PE / PE-Cyanine7 / PerCP-eFluor 710
- Super Bright 436 / 702
- Request custom conjugation available
Product Specific Information
The SIDI8BEE monoclonal antibody reacts with human and rhesus macaque CD8 beta.
CD8β associates with CD8α to form the CD8αβ heterodimer expressed on thymocytes and peripheral cytotoxic T cells.
The CD8 receptor complex binds to MHC class I and plays a role in T cell development and activation.
SIDI8BEE detects CD8β in both CD8αβ heterodimers and CD8ββ homodimers.
Cross-reactive to human and rhesus macaque CD8β; other primate species not tested.
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated for flow cytometry of human peripheral blood lymphocytes (5 µL per test).
A test is defined as the antibody amount that stains cells in a 100 µL final volume (10⁵–10⁸ cells/test).
NovaFluor dye compatibility:
Not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability.
CellBlox Plus Blocking Buffer (Cat. No. C001T06F01):
Required for optimal staining with NovaFluor conjugates.
Add 5 µL per sample or per 100 µL of cell sample for single-color controls.
Technology:
NovaFluor conjugates are based on Phiton™ technology using engineered nucleic acid dye structures for optimized fluorescence performance (Excitation: 509 nm; Emission: 614 nm; Laser: 488 nm).
Target Information
The CD8B antigen is a cell surface glycoprotein found on cytotoxic T lymphocytes.
Acts as a coreceptor with the T-cell receptor recognizing antigens presented by MHC class I molecules.
Functional forms include:
- Homodimer (αα)
- Heterodimer (αβ)
Both chains share homology with immunoglobulin variable light chains.
CD8B gene encodes beta chain isoforms; multiple spliced variants and a pseudogene exist on chromosome 2.
For Research Use Only.