
Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience
마우스 MHC Class I (H-2Kd/H-2Dd) 인식 단클론 항체로, PerCP-eFluor 710 형광체 결합. Flow cytometry 분석에 최적화되어 있으며, 0.25 µg/test로 사용 가능. 488 nm Blue Laser에서 여기, 710 nm에서 방출. 연구용으로만 사용.
- 카탈로그번호
- 46-5998-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience
Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710
Applications
- Flow Cytometry (Flow)
Tested Dilution: 0.25 µg/test
Publications: View 7 publications
Product Specifications
| 항목 | 내용 |
|---|---|
| Published species | Not Applicable |
| Host / Isotype | Mouse / IgG2a, kappa |
| Recommended Isotype Control | Mouse IgG2a kappa Isotype Control (eBM2a), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 34-1-2S |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation / Emission Max | 482 / 708 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping conditions | Wet ice |
| RRID | AB_2573822 |
Additional Formats
- Unconjugated
- APC
- Biotin
- eFluor 450
- FITC
- Functional Grade
- NovaFluor Blue 510
- NovaFluor Blue 585
- NovaFluor Blue 610-70S
- NovaFluor Blue 660-120S
- NovaFluor Red 710
- NovaFluor Yellow 570
- NovaFluor Yellow 660
- PE
- Request custom conjugation
Product Specific Information
The 34-1-2S monoclonal antibody reacts with mouse MHC class I, H-2Kd and H-2Dd. This cytotoxic antibody also cross-reacts with Kb, s, r, q, p.
Applications Reported: Flow cytometric analysis
Applications Tested: Tested by flow cytometric analysis of mouse splenocytes. Recommended ≤0.25 µg per test (100 µL final volume). Cell number may range from 10⁵ to 10⁸ cells/test. Titrate for optimal performance.
PerCP-eFluor® 710 emits at 710 nm and is excited with the blue laser (488 nm); can replace PerCP-Cyanine5.5. Recommended filter: 710/50 bandpass (695/40 acceptable). Ensure instrument compatibility.
Fixation:
Samples can be stored in IC Fixation Buffer (Product #00-822-49) or 1-step Fix/Lyse Solution (Product #00-5333-54) for up to 3 days at 4°C in the dark with minimal impact on brightness and FRET efficiency.
Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Filtration: 0.2 µm post-manufacturing filtered
Target Information
MHC class I alloantigen involved in antigen presentation to CD3/TCR and CD8-expressing T cells.
HLA and MHC antibodies are crucial in Immunopeptidomics for neoantigen identification via LC-MS/MS.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.



