CacheBy
Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience

상품 한눈에 보기

마우스 MHC Class I (H-2Kd/H-2Dd) 인식 단클론 항체로, PerCP-eFluor 710 형광체 결합. Flow cytometry 분석에 최적화되어 있으며, 0.25 µg/test로 사용 가능. 488 nm Blue Laser에서 여기, 710 nm에서 방출. 연구용으로만 사용.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
Thermo Fisher Scientific 46-5998-82 MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience 100 ug pk판매 단위 pk
재고 확인 필요
431,100원VAT 포함 474,210원
Thermo Fisher Scientific 46-5998-80 MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience 25 ug pk판매 단위 pk
재고 확인 필요
141,500원VAT 포함 155,650원

Thermo Fisher Scientific · Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710, eBioscience

Thermo Fisher Scientific MHC Class I (H-2Kd/H-2Dd) Monoclonal Antibody (34-1-2S), PerCP-eFluor 710

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 0.25 µg/test
Publications: View 7 publications


Product Specifications

항목 내용
Published species Not Applicable
Host / Isotype Mouse / IgG2a, kappa
Recommended Isotype Control Mouse IgG2a kappa Isotype Control (eBM2a), PerCP-eFluor™ 710, eBioscience™
Class Monoclonal
Type Antibody
Clone 34-1-2S
Conjugate PerCP-eFluor™ 710
Excitation / Emission Max 482 / 708 nm
Form Liquid
Concentration 0.2 mg/mL
Storage conditions 4°C, store in dark, DO NOT FREEZE
Shipping conditions Wet ice
RRID AB_2573822

Additional Formats


Product Specific Information

The 34-1-2S monoclonal antibody reacts with mouse MHC class I, H-2Kd and H-2Dd. This cytotoxic antibody also cross-reacts with Kb, s, r, q, p.

Applications Reported: Flow cytometric analysis
Applications Tested: Tested by flow cytometric analysis of mouse splenocytes. Recommended ≤0.25 µg per test (100 µL final volume). Cell number may range from 10⁵ to 10⁸ cells/test. Titrate for optimal performance.

PerCP-eFluor® 710 emits at 710 nm and is excited with the blue laser (488 nm); can replace PerCP-Cyanine5.5. Recommended filter: 710/50 bandpass (695/40 acceptable). Ensure instrument compatibility.

Fixation:
Samples can be stored in IC Fixation Buffer (Product #00-822-49) or 1-step Fix/Lyse Solution (Product #00-5333-54) for up to 3 days at 4°C in the dark with minimal impact on brightness and FRET efficiency.

Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Filtration: 0.2 µm post-manufacturing filtered


Target Information

MHC class I alloantigen involved in antigen presentation to CD3/TCR and CD8-expressing T cells.
HLA and MHC antibodies are crucial in Immunopeptidomics for neoantigen identification via LC-MS/MS.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0개

아직 등록된 문의가 없어요.