
Thermo Fisher Scientific CD278 (ICOS) Monoclonal Antibody (ISA-3), APC-eFluor 780, eBioscience
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Applications
Tested Dilution
Publications
Flow Cytometry (Flow)
5 µL (0.125 µg)/test
View 11 publications 11 publications
Functional Assay (Functional)
-
View 1 publication 1 publication
Product Specifications
Published species
Human
Host/Isotype
Mouse / IgG1, kappa
Recommended Isotype Control
Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), APC-eFluor™ 780, eBioscience™
Class
Monoclonal
Type
Antibody
Clone
ISA-3
Conjugate
APC-eFluor™ 780 APC-eFluor™ 780 APC-eFluor™ 780
View additional formats
- Unconjugated
- Alexa Fluor 700
- APC
- Biotin
- Brilliant UV 661
- eFluor 450
- FITC
- Functional Grade
- NovaFluor Red 660
- NovaFluor Red 710
- NovaFluor Yellow 700
- NovaFluor Yellow 730
- PE
- PE-Cyanine5.5
- PE-Cyanine7
- PE-eFluor 610
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Super Bright 645
- Super Bright 780
- Request custom conjugation
Excitation/Emission Max
756/785 nm View spectra
Form
Liquid
Concentration
5 µL/Test
Storage conditions
4° C, store in dark, DO NOT FREEZE!
Shipping conditions
Wet ice
RRID
AB_2573999
Product Specific Information
Description: The ISA-3 monoclonal antibody reacts with human ICOS (Inducible COStimulatory molecule), also known as H4, CRP-1 and AILIM. ICOS is a T cell specific activation molecule and a third member of the CD28/CTLA-4 family. Human ICOS has a relative molecular mass of 55-60 kDa, composed of 27 kDa and 29 kDa chains. Human ICOS on activated T cells has potent costimulatory activity for T cell activation and is required for humoral immune responses, in particular for memory B cell and plasma cell generation. ICOS binds to its ligand, B7h/B7RP-1 expressed on activated APCs (antigen presenting cells) and on a number of inflamed peripheral tissues. Plate-bound ISA-3 is costimulatory for T cells and induces production of IL-4, IL-5, IL-10 and other cytokines, but not IL-2. ISA-3 has the same reactivity pattern and characteristics as F44. ISA-3 was generated against the human ICOS antigen. C398.4A, anti-mouse ICOS/H4 (Product # 14-9949-82) , was shown to cross-react with human ICOS but binds to an epitope different from ISA-3. C398.4A stains activated cells brighter than ISA-3; however, it also exhibits higher staining of non-activated human peripheral blood or isolated PBMC. To achieve the brightest staining of ICOS on activated human T cells, please use Product # 13-9948-82 or Product # 12-9948-42 rather than Product # 11-9948-42 .
Applications Reported: This ISA-3 antibody has been reported for use in flow cytometric analysis.
Applications Tested: This ISA-3 antibody has been pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. This can be used at 5 µL (0.125 µg) per test. A test is defined as the amount (µg) of antibody that will stain a cell sample in a final volume of 100 µL. Cell number should be determined empirically but can range from 10^5 to 10^8 cells/test.
APC-eFluor 780 emits at 780 nm and is excited with the Red laser (633 nm). Please make sure that your instrument is capable of detecting this fluorochome.
Light sensitivity: This tandem is sensitive to photo-induced oxidation. Please protect this vial and stained samples from light.
Fixation: Samples can be stored in IC Fixation Buffer (Product # 00-8222) (100 µL cell sample + 100 µL IC Fixation Buffer) or 1-step Fix/Lyse Solution (Product # 00-5333) for up to 3 days in the dark at 4°C with minimal impact on brightness and FRET efficiency/compensation. Some generalizations regarding fluorophore performance after fixation can be made, but clone specific performance should be determined empirically.
Excitation: 633-647 nm; Emission: 780 nm; Laser: Red Laser.
Filtration: 0.2 µm post-manufacturing filtered.
Target Information
ICOS (CD278) encodes a protein that is a member of the CD28 and CTLA-4 cell-surface receptor family. It functions as a homodimer and has a crucial role in cell-cell signaling, immune responses, and the regulation of cell proliferation. ICOS has been linked to various disorders, including Immunodeficiency, Common Variable, 1 and Common Variable Immunodeficiency.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific CD1a Monoclonal Antibody (HI149), eFluor 450, eBioscience
195,500원

Thermo Fisher Scientific
Thermo Fisher Scientific CD284 (TLR4) Monoclonal Antibody (HTA125), APC-eFluor 780, eBioscience
290,400원

Thermo Fisher Scientific
Thermo Fisher Scientific CD278 (ICOS) Monoclonal Antibody (ISA-3), APC-eFluor 780, eBioscience
203,600원

Thermo Fisher Scientific
Thermo Fisher Scientific CD303a Monoclonal Antibody (201A), APC-eFluor 780, eBioscience
628,600원

Thermo Fisher Scientific
Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), APC-eFluor 780, eBioscience
650,100원
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제수단 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|