Thermo Fisher Scientific CD1c Monoclonal Antibody (L161), NovaFluor Blue 660-120S, eBioscience
인간 CD1c 항원 검출용 L161 단일클론 항체로, NovaFluor Blue 660-120S 형광체가 결합된 제품입니다. Flow Cytometry에 최적화되어 있으며, CellBlox Plus Blocking Buffer 포함. 높은 특이성과 안정성으로 면역세포 분석에 적합.
- 카탈로그번호
- H046T0xxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD1c Monoclonal Antibody (L161), NovaFluor Blue 660-120S, eBioscience
Thermo Fisher Scientific CD1c Monoclonal Antibody (L161), NovaFluor Blue 660-120S, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.2 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | L161 |
| Conjugate | NovaFluor™ Blue 660-120S |
| Excitation / Emission Max | 492 / 665 nm |
| Form | Liquid |
| Concentration | 0.2 µg/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| RRID | AB_3098551 (AB_2925944) |
Additional Formats
- APC
- FITC
- NovaFluor Blue 610-70S
- NovaFluor Blue 690
- NovaFluor Red 710
- NovaFluor Red 725
- NovaFluor Red 755
- NovaFluor Yellow 610
- NovaFluor Yellow 700
- NovaFluor Yellow 730
- NovaFluor Yellow 755
- PE
- PE-Cyanine7
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Super Bright 645
- Request custom conjugation available
Product Specific Information
This L161 monoclonal antibody detects CD1c (BDCA-1), a glycoprotein noncovalently linked to beta-2 microglobulin on thymocytes and antigen-presenting cells such as dendritic and Langerhans cells. It is also expressed on certain circulating and marginal zone B cells, as well as in lymph nodes and germinal centers. CD1c is involved in presenting lipid antigens (e.g., microbial fatty acids) to effector T cells during the adaptive immune response. Alternative splicing yields three isoforms: soluble, membrane, and cytoplasmic/soluble.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested on normal human peripheral blood cells. Recommended use at 5 µL (0.06 µg) per test in a final volume of 100 µL.
Note:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assessment.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining with NovaFluor conjugates.
- Add 5 µL per sample before combining with cells. For single-color controls, use 5 µL per 100 µL cell sample (10³–10⁸ cells).
NovaFluor Technology:
Based on Phiton™ dye structures engineered for optimized fluorescence signatures and minimal spectral spillover.
Excitation: 509 nm; Emission: 665 nm; Laser: 488 nm (Blue)
Target Information
The CD1 family comprises transmembrane glycoproteins structurally related to MHC proteins, forming heterodimers with beta-2-microglobulin. These proteins present lipid and glycolipid antigens to T cells. Human CD1 genes are clustered on chromosome 1 and differ in localization and ligand specificity. CD1c localizes to endosomes and lysosomes via a tyrosine-based motif and requires vesicular acidification for lipid antigen binding.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기