Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, Alexa Fluor 488, eBioscience
원본

Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, Alexa Fluor 488, eBioscience

상품 한눈에 보기

Syrian hamster IgG 동종 대조 항체로 Alexa Fluor 488 형광 표지. Flow cytometry 및 IHC용 음성 대조로 사용. 비특이적 결합 구분에 유용. 0.5 mg/mL 농도, 4°C 암소 보관. 연구용 전용 시약.

카탈로그번호
53-4914-80
카테고리
Antibodies
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 01:01
Thermo Fisher Scientific 53-4914-80 Syrian Hamster IgG Isotype Control, Alexa Fluor 488, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
183,800원VAT 포함 202,180원

Thermo Fisher Scientific · Thermo Fisher Scientific Syrian Hamster IgG Isotype Control, Alexa Fluor 488, eBioscience

Applications and Tested Dilution

Application Tested Dilution
Immunohistochemistry (IHC) Assay-Dependent
Flow Cytometry (Flow) Assay-Dependent
Control (Ctrl) Assay-Dependent

Product Specifications

항목 내용
Host/Isotype Syrian hamster / IgG
Class Polyclonal
Type Isotype Control
Conjugate Alexa Fluor™ 488
Excitation/Emission Max 499 / 520 nm
Form Liquid
Concentration 0.5 mg/mL
Purification Affinity chromatography
Storage buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage conditions 4°C, store in dark, DO NOT FREEZE!
Shipping conditions Ambient (domestic); Wet ice (international)
RRID AB_1582207

Product Specific Information

This hamster IgG fraction was purified by affinity chromatography from normal Golden Syrian hamster serum.

Applications Reported:
Reported for use in flow cytometric analysis and immunohistochemical staining.

Applications Tested:
This isotype control antibody has been tested by flow cytometric analysis of mouse splenocytes and normal human peripheral blood.
Use the isotype control at the same concentration as the experimental antibody.

Fluorescence Properties:

  • Excitation: 488 nm
  • Emission: 519 nm
  • Laser: Blue Laser

Filtration:
0.2 µm post-manufacturing filtered.


Target Information

The isotype of a primary antibody and the application it is used in can result in background staining.
Primary antibody background noise may be caused by binding to Fc receptors on target cells, non-specific interactions with cellular components, or cell autofluorescence.

Isotype control antibodies serve as negative controls to distinguish non-specific background from specific antibody signals.
They have no relevant specificity to a target antigen and are most commonly used in flow cytometry, but are also applicable in ChIP, IHC, and gel shift assays.

Isotype controls should match the primary antibody species and isotype to ensure accurate determination of specific staining.
When using directly labeled primary antibodies, the isotype control should be conjugated with the same label.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.