Thermo Fisher Scientific PolarScreen Vitamin D Receptor Competitor Assay Kit, Red
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
A15907 | - | Thermo Fisher Scientific A15907 PolarScreen Vitamin D Receptor Competitor Assay Kit, Red Each pk | 재고문의 | pk | 2,777,000원 | - | 3,054,700원 |
다른 상품 둘러보기
Thermo Scientific™
PolarScreen™ Vitamin D Receptor Competitor Assay Kit, Red
The PolarScreen™ Vitamin D Receptor Competitor Assay Kit, Red, provides a sensitive and efficient method for high-throughput, fluorescence polarization-based screening자세히 알아보기
The PolarScreen™ Vitamin D Receptor Competitor Assay Kit, Red, provides a sensitive and efficient method for high-throughput, fluorescence polarization-based screening of potential vitamin D receptor (VDR) ligands. The kit uses insect cell-expressed, human full-length VDR (also available separately) and a novel, high-affinity, fluorescent VDR ligand (Fluormone™ VDR Red) in a homogenous, mix-and-read assay format.
This kit produces a red color read-out and is suitable to determine the IC50s of competitive compounds. For additional information or assistance contact us at drugdiscoverytech@lifetech.com.
The PolarScreen Vitamine D Receptor Competitor Assay is:
- Complete & ready-to-use out of the box—all reagents included, just add your test compounds
- High throughput compatible—fluorescence polarization assays in a 384-well plate
- Convenient—components available in bulk sizes for larger screening needs
How the Assay Works
VDR is added to a fluorescent VDR ligand (Fluormone VDR Red) to form a receptor/tracer complex, resulting in a high polarization value. This complex is then added to individual test compounds in microwell plates. Competitors displace the tracer from the complex, causing the fluorescent ligand to tumble more rapidly during its fluorescence lifetime, resulting in a low polarization value. Noncompetitors will not displace the fluorescent ligand from the complex; therefore, the polarization value will remain high. The shift in polarization value in the presence of test compounds is used to determine relative affinity of test compounds for VDR (see figure).
Contact us for bulk quantities or for assistance with other nuclear receptor assay needs, from assay development to library screening and beyond.
사양
수량800 x 20 μL assays
제품라인PolarScreen™
용도(애플리케이션)Competitive Binding Assay, Nuclear Receptor Assay
리간드VDR
제품 유형Vitamin D Receptor Competitor Assay Kit
No. of Assays800 x 20 μL Assays
Unit SizeEach
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|