Thermo Fisher Scientific GlobalFiler IQC PCR Amplification Kit

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
A43565-Thermo Fisher Scientific A43565 GlobalFiler IQC PCR Amplification Kit Each pk재고문의pk0-0

Applied Biosystems™

GlobalFiler™ IQC PCR Amplification Kit

The GlobalFiler IQC PCR Amplification Kit is a 6-dye, 24-locus STR kit that combines maximum compatibility with global databasing loci자세히 알아보기

The GlobalFiler IQC PCR Amplification Kit is a 6-dye, 24-locus STR kit that combines maximum compatibility with global databasing loci standards. It provides superior discrimination power and an internal quality control (IQC) system, helping forensic DNA labs worldwide maximize information recovery and improve overall efficiency. The GlobalFiler IQC kit was specifically developed to maintain the performance and core marker set of the GlobalFiler kit while enabling an assessment of sample quality in the STR profile. It is part of a fully integrated and validated forensic DNA workflow backed by best-in-class global training, service, and support. This kit is optimized for casework samples; for database and single-source samples, please see our GlobalFiler Express PCR Amplification Kit.

Features of the GlobalFiler IQC PCR Amplification Kit include:
• Internal quality control (IQC) system enables detection of and discrimination between amplification inhibition and DNA sample degradation and an in-sample positive amplification control, providing actionable information
• Efficient protocols minimize amplification time compared to previous-generation kits
• An optimized buffer system and expanded DNA input volume delivers maximum sensitivity for trace/low level DNA samples
• Enhanced intracolor balance simplifies interpretation of mixture samples
• The inclusion of 10 mini-STRs maximizes results from degraded samples (<220 bp)
• Contains all markers recommended for inclusion by the CODIS Core Loci Working Group, including all markers commonly used in Europe, for maximum global database compatibility
• Improved data interpretation with reduced pull-up edits and off-scale data recovery when combined with 3500 Data Collection Software v4.0 and GeneMapper ID-X Software 1.6
• Manufactured to IS0 18385 standards

The GlobalFiler IQC kit is a robust and reliable single-amplification STR multiplex kit optimized for use with the most challenging casework samples. The kit leverages six dyes for the incorporation of additional markers, generating a highly discriminating kit for use by the forensic community. The kit contains all of the markers included in the major global databases, including 10 mini-STRs, to help deliver optimized results with even highly degraded samples.

Developed specifically for casework applications, the GlobalFiler kit contains a buffer system that delivers greater sensitivity for enhanced performance with inhibited and low-concentration DNA samples. The addition of the IQC provides more insight into sample quality to assist in distinguishing between inhibition and degradation while also providing a positive control for amplification. The GlobalFiler IQC kit utilizes the latest advances in oligo synthesis and purification, which provide a clean baseline and a balanced profile, resulting in simplified data analysis. Maintenance of the NGM Select and Identifiler primer sequences helps ensure maximum concordance with previously typed samples. In addition, the GlobalFiler IQC kit contains multiple gender markers to enable accurate typing of male samples, even highly degraded or Y-negative samples, while increased genotyping accuracy is obtained with the expansion of the allelic ladder allele ranges to include all rare alleles as described in the literature (STRbase).

Experience matters
Thermo Fisher Scientific designs and validates its reagents, instruments, and data analysis software together as an integrated system for DNA testing. Technical service scientists and field application specialists are available to answer your technical questions, review data, and make recommendations on how to perform assays and troubleshoot results. All of these resources help ensure success when using Applied Biosystems human identification solutions in your laboratory.

For licensing and limited use restrictions visit thermofisher.com/HIDlicensing.

사양

라벨 또는 염료6-FAM, LIZ, NED, SID, TAZ, VIC

제품라인GlobalFiler™

제품 유형PCR Amplification Kit

수량200 reactions

배송 조건Dry Ice

타겟 위치Amelogenin, CSF1PO, D10S1248, D12S391, D13S317, D16S539, D18S51, D19S433, D1S1656, D21S11, D22S1045, D2S1338, D2S441, D3S1358, D5S818, D7S820, D8S1179, DYS391, FGA, IQC-Large, IQC-Small, SE33, TH01, TPOX, Y indel, vWA

Unit SizeEach


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0