CacheBy
Thermo Fisher Scientific IL-12/IL-23 p40 Monoclonal Antibody (C17.8), eFluor 660, eBioscience
원본

Thermo Fisher Scientific IL-12/IL-23 p40 Monoclonal Antibody (C17.8), eFluor 660, eBioscience

상품 한눈에 보기

IL-12 및 IL-23 p40 서브유닛을 인식하는 단클론 항체로, Flow Cytometry 및 중화 실험에 적합합니다. eFluor 660 형광 표지로 적색 레이저(633 nm)에서 검출되며, 0.125 µg/test 농도로 사용 가능합니다. 연구용으로만 사용됩니다.

카탈로그번호
50-7123-8x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오전 09:30
Thermo Fisher Scientific 50-7123-82 IL-12/IL-23 p40 Monoclonal Antibody (C17.8), eFluor 660, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
599,300원VAT 포함 659,230원
Thermo Fisher Scientific 50-7123-80 IL-12/IL-23 p40 Monoclonal Antibody (C17.8), eFluor 660, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
219,700원VAT 포함 241,670원

Thermo Fisher Scientific · Thermo Fisher Scientific IL-12/IL-23 p40 Monoclonal Antibody (C17.8), eFluor 660, eBioscience

Applications and Tested Dilution

Application Tested Dilution Publications
Flow Cytometry (Flow) 0.125 µg/test View 6 publications
Neutralization (Neu) - View 1 publication

Product Specifications

항목 내용
Published species Human, Mouse
Host / Isotype Rat / IgG2a, kappa
Recommended Isotype Control Rat IgG2a kappa Isotype Control (eBR2a), eFluor™ 660, eBioscience™
Class Monoclonal
Type Antibody
Clone C17.8
Conjugate eFluor™ 660
Excitation/Emission Max 651 / 668 nm
Form Liquid
Concentration 0.2 mg/mL
Storage conditions 4°C, store in dark, DO NOT FREEZE
Shipping conditions Wet ice
RRID AB_11218284

Additional Formats


Product Specific Information

The C17.8 antibody reacts with the p40 subunit of IL-12 and IL-23. It neutralizes IL-12 and IL-23 bioactivity. For specific neutralization of IL-23 only, clone G23-8 (anti-mouse IL-23 p19) is recommended.

IL-12 is a 70 kDa heterodimeric cytokine composed of two chains, p40 and p35, secreted by activated monocytes, macrophages, and dendritic cells. IL-23 is a heterodimer composed of p19 and p40 proteins, expressed by activated dendritic cells.

Applications Reported: Intracellular staining followed by flow cytometric analysis.
Applications Tested: Tested by intracellular staining and flow cytometric analysis of stimulated mouse cells at ≤0.125 µg/test.
A test is defined as the amount of antibody that stains a sample in 100 µL volume. Cell number may range from 10⁵–10⁸ cells/test. Antibody titration is recommended for optimal performance.

Fluorochrome Information:
eFluor® 660 is a replacement for Alexa Fluor® 647. It emits at 659 nm and is excited with a 633 nm red laser. Ensure your instrument can detect this fluorochrome.

  • Excitation: 633–647 nm
  • Emission: 668 nm
  • Laser: Red Laser
  • Filtration: 0.2 µm post-manufacturing filtered

Target Information

IL-12 is an interleukin produced by dendritic cells, neutrophils, macrophages, and lymphoblastoid cells upon antigenic stimulation. It is a heterodimeric cytokine encoded by IL-12A (p35) and IL-12B (p40).
IL-23 shares the p40 subunit with IL-12 and includes an IL-23A (p19) subunit.

Functions:

  • IL-12 increases endothelial adhesion molecule-1 expression and directs leukocytes toward tumors.
  • IL-23 stimulates memory T-cells and supports Th17 cell function, promoting neutrophil chemokine and pro-inflammatory cytokine expression.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.