Servicebio Pipette
다양한 용량 범위와 멀티컬러 표시로 구분이 쉬운 Servicebio 피펫은 단일 및 다채널 옵션을 제공합니다. 인체공학적 설계로 피로를 줄이고, ISO 8655-2:2022 기준에 따라 정밀하게 교정되어 높은 정확도를 보장합니다. 대부분의 팁과 호환되며 CE 인증을 획득했습니다.
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Product Introduction
A pipette is a device used to transfer liquid quantitatively. In analytical testing research, it is generally used for small or microliter volumes.
There are 8 colors to choose from, and exclusive lucky colors can be customized.
SPIP-20L Pipette Compatibility Chart
| Pipette | Pipette Tips Spec. | Details | Pipette Tips Cat. No. |
|---|---|---|---|
| SPIP-20L | 10 μL | Racked (Sterile, DNase&RNase Free) | TP-10-C |
| Bagged (DNase&RNase Free) | TP-10 | ||
| 10 μL Long, Racked (Sterile, DNase&RNase Free) | TP-10P-C | ||
| Bagged (DNase&RNase Free) | TP-10P | ||
| 10 μL with Filter (Unable to aspirate up to 20 μL) | TP-10-C-F | ||
| 10 μL Long with Filter (Able to aspirate up to 20 μL) | TP-10P-C-F |
Product Features
- Multiple volume ranges with multi-color markings; single and multi-channel options.
- Lightweight spring for easy operation.
- Equipped with Servicebio tips for good air tightness and accurate transfer.
- Compatible with most tips on the market.
- CE certified; complies with ISO 8655-2:2022 international standard.
Product Parameters
| Product Name | Product No. | Nominal Volume | Volume Range | Increment |
|---|---|---|---|---|
| Single Channel Pipette | SPIP-2.5 | 2.5 μL | 0.1–2.5 μL | 0.05 μL |
| SPIP-10 | 10 μL | 1–10 μL | 0.1 μL | |
| SPIP-20L | 20 μL | 2–20 μL (for 10 μL and 10 μL-long tips) | 0.1 μL | |
| SPIP-20 | 20 μL | 2–20 μL (for 200 μL tips) | 0.1 μL | |
| SPIP-50 | 50 μL | 5–50 μL (for 10 μL-long and 10 μL tips) | 0.5 μL | |
| SPIP-100 | 100 μL | 10–100 μL | 1 μL | |
| SPIP-200 | 200 μL | 20–200 μL | 1 μL | |
| SPIP-1000 | 1000 μL | 100–1000 μL | 5 μL | |
| SPIP-5000 | 5000 μL | 1000–5000 μL | 50 μL | |
| SPIP-10000 | 10 mL | 1–10 mL | 100 μL | |
| 8-Channel Pipette | SPIP-B10 | 10 μL | 1–10 μL | 0.1 μL |
| SPIP-B20L | 20 μL | 2–20 μL | 0.1 μL | |
| SPIP-B50 | 50 μL | 5–50 μL | 0.5 μL | |
| SPIP-B100 | 100 μL | 10–100 μL | 1 μL | |
| SPIP-B300 | 300 μL | 50–300 μL | 1 μL | |
| SPIP-B1000 | 1000 μL | 100–1000 μL | 5 μL |
Additional Product Features
- Single channel: 0.1–2.5 μL, 1–10 μL, 2–20 μL, 5–50 μL, 10–100 μL, 20–200 μL, 100–1000 μL, 1000–5000 μL, 1–10 mL; 10 sizes available.
- Multi-channel: 1–10 μL, 2–20 μL, 5–50 μL, 10–100 μL, 50–300 μL, 100–1000 μL; 6 sizes available.
- Lightweight ergonomic design reduces hand fatigue; light spring mechanism for easy operation.
- Large digital display shows volume clearly.
- Made of high-strength, corrosion-resistant, UV-stable materials.
- Color-coded handles for easy identification.
- Compatible with most pipette tips on the market.
- Calibrated according to EN/ISO8655 standard with strict quality control.
Pipette Structure (from image)
- Push Button / Volume Turn Button (Top Cap)
- Push Rod
- Handle Grippy
- Tip Ejection Button
- Handle
- Volume Display
- Tip Ejection Pipe
- Pipe Tip
Device marking:
Servicebio
2–20 μL Adjustable Pipette
Display: 2.0Pipette Operation
Forward Technique (for low-density liquids)
- Press the push button to the first STOP.
- Slowly release to the ready position to aspirate liquid.
- Deliver liquid by pressing to the first STOP, then continue to the second STOP to empty.
- Release to ready position and change tip if needed.
Reverse Technique (for high-viscosity or volatile liquids)
- Depress button to the second STOP, then release slowly to aspirate slightly more than preset volume.
- Press to the first STOP to dispense preset volume.
- Discard remaining liquid with the tip.
Position Reference: Ready Position → First STOP → Second STOP
Calibration and Adjustment
Use the Service Tool as shown:
- Turn clockwise to increase volume.
- Turn counterclockwise to decrease volume.
- Calibrate 1–2 times per year depending on usage.
Note: “Mantissa (Increment)” refers to the product data sheet.
Storage and Transportation
Store and transport at room temperature.
Notice
- Ensure pipette and tips are at the same temperature before use. Hold upright and immerse tip 2–3 mm below liquid surface. Pre-wet tip for viscous or dense liquids.
- Do not invert or lay flat when tip contains liquid. Use a pipette stand.
- Operate within the specified volume range.
- Apply maintenance oil to sealing ring for long-term storage.
- For disassembly or repair, contact a professional technician.
Pipette and Tip Adaptation Table
Pipette Specifications
| Cat. No. | SPP-2.5 | SPP-10 | SPP-20 | SPP-20L | SPP-50 | SPP-100 | SPP-200 | SPP-1000 | SPP-5000 | SPP-10000 | SPP-810 | SPP-820L | SPP-850 | SPP-830 | SPP-830L | SPP-81000 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette | 8-channel Pipette |
| Spec. | 0.1–2.5 μL | 0.5–10 μL | 2–20 μL (for long tips, 10 μL tips) | 5–50 μL (for long tips, 10 μL tips) | 10–100 μL | 20–200 μL | 100–1000 μL | 0.5–5000 μL | 0.5–10000 μL | 0.5–10000 μL | 0.5–10 μL (for long tips, 10 μL tips) | 2–20 μL (for long tips, 10 μL tips) | 5–50 μL | 10–300 μL | 10–300 μL | 10–1000 μL |
Standard Tips
| Cat. No. | Spec. | SPP-2.5 | SPP-10 | SPP-20 | SPP-20L | SPP-50 | SPP-100 | SPP-200 | SPP-1000 | SPP-5000 | SPP-10000 | SPP-810 | SPP-820L | SPP-850 | SPP-830 | SPP-830L | SPP-81000 |
|-----------|--------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|
| TP-10-C / TP-10 | 10 μL | √ | √ | √ | (Unable to aspirate 50 μL) | | | | | | | √ | √ | (Unable to aspirate 50 μL) |
| TP-10P-C / TP-10P | 10 μL Long | √ | √ | √ | (Unable to aspirate 50 μL) | | | | | | | √ | √ | (Unable to aspirate 50 μL) |
| TP-200-C / TP-200 | 200 μL | | | | | √ | √ | √ | | | | | | (Unable to aspirate 300 μL) |
| TP-200P-C / TP-200P | 200 μL Long | | | | | √ | √ | √ | | | | | | (Unable to aspirate 300 μL) |
| TP-1000-C / TP-1000 | 1000 μL | | | | | | | √ | √ | | | | | | | |
| TP-1000P-C / TP-1000P | 1000 μL Long | | | | | | | √ | √ | | | | | | | |
| TP-5000L-C / TP-5000L | 5 mL Wide Mouth | | | | | | | | | √ | | | | | | |
| TP-10000-C / TP-10000 | 10 mL | | | | | | | | | | √ | | | | | |
Filter Tips
| Cat. No. | Spec. | SPP-2.5 | SPP-10 | SPP-20 | SPP-20L | SPP-50 | SPP-100 | SPP-200 | SPP-1000 | SPP-5000 | SPP-10000 | SPP-810 | SPP-820L | SPP-850 | SPP-830 | SPP-830L | SPP-81000 |
|-----------|--------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|----------|
| TP-10-C-F | 10 μL | √ | √ | √ | (Unable to aspirate 20 μL) | (Unable to aspirate 50 μL) | | | | | | √ | √ | (Unable to aspirate 50 μL) |
| TP-10P-C-F | 10 μL Long | √ | √ | √ | (Able to aspirate 20 μL) | (Unable to aspirate 50 μL) | | | | | | √ | √ | (Unable to aspirate 50 μL) |
| TP-20-C-F | 20 μL | | | √ | √ | (Unable to aspirate 100 μL) | | | | | | | | √ | (Unable to aspirate 100 μL) |
| TP-100-C-F | 100 μL | | | | | √ | √ | (Unable to aspirate 200 μL) | | | | | | | √ | (Unable to aspirate 300 μL) |
| TP-200-C-F | 200 μL | | | | | | √ | √ | | | | | | | | (Unable to aspirate 300 μL) |
| TP-200P-C-F | 200 μL Long | | | | | | √ | √ | | | | | | | | (Unable to aspirate 300 μL) |
| TP-1000S-C-F | 1000 μL | | | | | | | √ | √ | | | | | | | |
| TP-1000P-C-F | 1000 μL Long | | | | | | | √ | √ | | | | | | | |
| TP-5000L-C-F | 5 mL Wide Mouth | | | | | | | | | √ | | | | | | |
| TP-10000-C-F | 10 mL | | | | | | | | | | √ | | | | | |
제품 이미지





배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|