Thermo Fisher Scientific IgM Monoclonal Antibody (SA-DA4), Brilliant Violet 480, eBioscience
인간 IgM의 μ heavy chain을 인식하는 단클론 항체로, Brilliant Violet 480 형광체로 결합되어 있습니다. Flow Cytometry에 최적화되어 있으며, 비특이적 염색을 최소화하기 위해 sodium citrate 항응고제 사용을 권장합니다. 4°C 암소 보관, 동결 금지.
- 카탈로그번호
- 414-9998-4x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific IgM Monoclonal Antibody (SA-DA4), Brilliant Violet 480, eBioscience
Thermo Fisher Scientific IgM Monoclonal Antibody (SA-DA4), Brilliant Violet 480, eBioscience™
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (0.25 µg)/test
Publications: -
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host/Isotype | Mouse / IgG1, kappa |
| Recommended Isotype Control | Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), Brilliant Violet™ 480, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | SA-DA4 |
| Conjugate | Brilliant Violet™ 480 |
| Excitation/Emission Max | 437 / 478 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2, with BSA |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Wet ice |
| RRID | AB_3074110 |
Additional Formats
- Unconjugated
- APC
- Biotin
- Brilliant UV 395
- Brilliant UV 737
- Brilliant Violet 605
- Brilliant Violet 786
- eFluor 450
- FITC
- PE
- PE-Cyanine7
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Request custom conjugation
Product Specific Information
The SA-DA4 monoclonal antibody reacts with the mu heavy chain of human IgM. It does not react with other classes of human immunoglobulin such as IgD, IgG, or IgA. IgM is expressed intracellularly during early B lymphopoiesis and on the surface of mature B cells.
Testing indicates variability in staining of non-B cell populations, attributed to donor variability and anticoagulant type. Sodium citrate is recommended to minimize non-specific staining.
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-diluted and tested by flow cytometry on human peripheral blood cells. Use at 5 µL (0.25 µg)/test in a final volume of 100 µL. Cell number may range from 10⁵ to 10⁸ cells/test.
Brilliant Violet™ 480 (BV480) emits at 479 nm and is optimized for cytometers with a violet (405 nm) laser. Confirm instrument compatibility before use.
For panels including multiple polymer dye-conjugated antibodies, use Super Bright Complete Staining Buffer (Product # SB-4401-42) or Brilliant Stain Buffer™ (Product # 00-4409-75) to minimize non-specific interactions.
BV480 is not compatible with methanol-based fixation.
Excitation: 440 nm
Emission: 479 nm
Laser: Violet Laser
BRILLIANT VIOLET™ is a trademark of Becton, Dickinson and Company, used under license. Powered by Sirigen™.
Target Information
IgM is expressed intracellularly during early B lymphopoiesis and on the surface of mature B cells in bone marrow and peripheral blood.
For Research Use Only. Not for use in diagnostic procedures or resale without authorization.