인간 HLA-A, B, C 항원을 인식하는 W6/32 단클론 항체로, PerCP-eFluor 710 형광체로 결합되어 있습니다. 유세포분석(Flow Cytometry)에 최적화되어 있으며, 488 nm 레이저로 여기되어 710 nm에서 방출됩니다. 세포면 MHC class I 분석에 적합합니다.

카탈로그번호
46-9983-42
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오후 06:53
Thermo Fisher Scientific 46-9983-42 HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
576,800원VAT 포함 634,480원

Thermo Fisher Scientific · Thermo Fisher Scientific HLA-ABC Monoclonal Antibody (W6/32), PerCP-eFluor 710, eBioscience

Applications

Immunohistochemistry (Frozen) (IHC (F))

Flow Cytometry (Flow)


Product Specifications

항목 내용
Species Reactivity Human
Published Species Human
Host / Isotype Mouse / IgG2a, kappa
Recommended Isotype Control Mouse IgG2a kappa Isotype Control (eBM2a), PerCP-eFluor™ 710, eBioscience™
Class Monoclonal
Type Antibody
Clone W6/32
Conjugate PerCP-eFluor™ 710
Excitation/Emission Max 482 / 708 nm
Form Liquid
Concentration 5 µL/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_10804486

Additional Available Formats

  • Unconjugated
  • Alexa Fluor 700
  • APC
  • Biotin
  • Brilliant UV 395 / 615 / 737
  • Brilliant Violet 650 / 786
  • FITC
  • Functional Grade
  • NovaFluor Blue 510 / 610-70S / 660-120S / 690
  • NovaFluor Red 710 / 725 / 755
  • NovaFluor Yellow 590 / 660 / 755
  • PE / PE-Cyanine5 / PE-Cyanine7
  • Super Bright 436 / 600 / 702
  • Request custom conjugation

Product Specific Information

The W6/32 monoclonal antibody reacts with human MHC class I antigens (HLA-A, B, C).
These antigens, associated with β2-microglobulin, are expressed by all human nucleated cells and play a key role in cell-mediated immune responses and tumor surveillance.
W6/32 recognizes a non-polymorphic epitope shared among HLA-A, B, and C loci and immunoprecipitates both 43 kDa and 11–12 kDa chains. Cross-reactivity is observed in baboon, rhesus, and cynomolgus monkey.

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and validated for flow cytometry using normal human peripheral blood cells.
Use 5 µL (0.25 µg) per test in a final volume of 100 µL. Suitable for 10⁵–10⁸ cells/test.

Fluorochrome Information:
PerCP-eFluor™ 710 can replace PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.

  • Excitation: 488 nm (Blue laser)
  • Emission: 710 nm
  • Recommended filters: 685 LP dichroic mirror and 710/40 band pass filter (695/40 acceptable alternative)

Fixation Stability:
Stable after staining when exposed to 2% formaldehyde overnight at 4°C. Evaluate for alternative fixation protocols.

Filtration: 0.2 µm post-manufacturing filtered.


Target Information

HLA-class I major histocompatibility (MHC) antigens are intrinsic membrane glycoproteins expressed on nucleated cells and associated with β2-microglobulin.
They present foreign peptides to cytotoxic T cells, playing a critical role in antiviral and antitumor immunity.
Human HLA-class I molecules include HLA-A, HLA-B, and HLA-C.
HLA and MHC antibodies are essential tools in immunopeptidomics for identifying and characterizing neoantigens via LC-MS/MS.

For Research Use Only. Not for use in diagnostic procedures or resale without authorization.