
Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 585, eBioscience
HLA-A3 단백질을 인식하는 마우스 단클론 항체로, NovaFluor Blue 585 형광으로 결합되어 유세포 분석(Flow Cytometry)에 적합합니다. CellBlox Plus Blocking Buffer와 함께 제공되며, 4°C 암소 보관이 필요합니다. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- H071T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Blue 585, eBioscience
Applications
- Flow Cytometry (Flow)
Tested dilution: 5 µL (0.6 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG2a, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | GAP.A3 |
| Conjugate | NovaFluor™ Blue 585 |
| Excitation / Emission Max | 493 / 586 nm |
| Form | Liquid |
| Concentration | 0.6 µg/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| RRID | AB_3098777 (AB_2937270) |
Additional Formats
- APC
- FITC
- NovaFluor Blue 510
- NovaFluor Blue 610-70S
- NovaFluor Blue 660-120S
- NovaFluor Blue 690
- NovaFluor Red 710
- NovaFluor Red 725
- NovaFluor Yellow 570
- NovaFluor Yellow 660
- NovaFluor Yellow 730
- NovaFluor Yellow 755
- PE
- Super Bright 436
- Super Bright 600
- Custom conjugation available
Product Specific Information
The monoclonal antibody GAP.A3 reacts with the human major histocompatibility complex (MHC) class I molecule HLA-A3, a member of the HLA-A family. HLA-A3 has two subtypes (HLA-A3.1 and HLA-A3.2) differing at amino acid positions 152 and 156. MHC class I molecules are expressed on all nucleated cells and present intracellular peptides to cytotoxic T lymphocytes.
HLA-A3 is expressed by 15–25% of cancer patients and is known to bind the tumor-associated antigen human telomerase reverse transcriptase (hTERT).
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested on normal human peripheral blood cells.
Recommended use: 5 µL (0.6 µg) per 100 µL cell sample (10⁵–10⁸ cells/test).
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assays with NovaFluor dyes.
- Use CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) for optimal staining. Add 5 µL per sample to antibody cocktails before mixing with cells.
NovaFluor conjugates are based on Phiton™ technology, utilizing engineered nucleic acid dye structures designed to minimize spillover and spectral spread.
Excitation: 494 nm | Emission: 585 nm | Laser: 488 nm (Blue)
Target Information
HLA-A is a class I heavy chain molecule forming a heterodimer with β2-microglobulin. It plays a key role in antigen presentation by displaying peptides derived from intracellular proteins. Expressed on nearly all nucleated cells, the heavy chain (~45 kDa) gene consists of 8 exons encoding leader, peptide-binding, transmembrane, and cytoplasmic regions.
Polymorphisms in exons 2 and 3 determine peptide-binding specificity, relevant for transplantation compatibility testing.
HLA and MHC antibodies are essential tools in Immunopeptidomics, aiding in neoantigen identification via LC-MS/MS.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
