CacheBy
Thermo Fisher Scientific ApoA1 Polyclonal Antibody, Biotin, PeproTech
원본

Thermo Fisher Scientific ApoA1 Polyclonal Antibody, Biotin, PeproTech

상품 한눈에 보기

Human ApoA-I 단백질을 인식하는 Biotin 표지 토끼 폴리클로날 항체로, Western Blot과 ELISA에 적합합니다. 항원 친화 크로마토그래피로 정제되었으며, 동결건조 형태로 제공됩니다. 연구용으로만 사용 가능합니다.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
ADBIX 2026 전시회10/28~30 코엑스 · 사전등록 안내자세히보기
Thermo Fisher Scientific 500-P331BT-50UG ApoA1 Polyclonal Antibody, Biotin, PeproTech 50 ug pk판매 단위 pk
재고 확인 필요
411,600원VAT 포함 452,760원
Thermo Fisher Scientific 500-P331BT-25UG ApoA1 Polyclonal Antibody, Biotin, PeproTech 25 ug pk판매 단위 pk
재고 확인 필요
328,500원VAT 포함 361,350원

Thermo Fisher Scientific · Thermo Fisher Scientific ApoA1 Polyclonal Antibody, Biotin, PeproTech

Applications

Western Blot (WB)

  • 권장 농도: 0.1–0.2 µg/mL

ELISA

  • 권장 농도: 0.25–1.0 µg/mL

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Rabbit
Class Polyclonal
Type Antibody
Immunogen E.coli-derived, 28.2 kDa Recombinant Human ApoA-I
Conjugate Biotin
Form Lyophilized
Concentration 0.1–1.0 mg/mL
Purification Antigen affinity chromatography
Storage Buffer PBS
Contains No preservative
Storage Conditions -20°C
Shipping Conditions Ambient
RRID AB_2930466

Product Specific Information

Amino Acid Sequence of Recombinant Protein:
MDEPPQSPWD RVKDLATVYV DVLKDSGRDY VSQFEGSALG KQLNLKLLDN WDSVTSTFSK LREQLGPVTQ EFWDNLEKET EGLRQEMSKD LEEVKAKVQP YLDDFQKKWQ EEMELYRQKV EPLRAELQEG ARQKLHELQE KLSPLGEEMR DRARAHVDAL RTHLAPYSDE LRQRLAARLE ALKENGGARL AEYHAKATEH LSTLSEKAKP ALEDLRQGLL PVLESFKVSF LSALEEYTKK LNTQ.

Preparation:
Produced from sera of rabbits immunized with highly pure Recombinant Human ApoA-I. Anti-Human ApoA-I-specific antibody was purified by affinity chromatography and then biotinylated.

Sandwich ELISA:
To detect Human ApoA-I by sandwich ELISA (100 µL/well), use 0.25–1.0 µg/mL of this antibody. When used with PeproTech Polyclonal Anti-Human ApoA-I (500-P331) as a capture antibody, it enables detection of 2000–4000 pg/mL of Recombinant Human ApoA-I.

Western Blot:
For detection of Human ApoA-I by Western Blot, use 0.1–0.2 µg/mL of this antibody. With compatible detection reagents, the detection limit for Recombinant Human ApoA-I is 1.5–3.0 ng/lane under reducing or non-reducing conditions.

Packaging:
500-P331BT-1MG is supplied as 2 × 500 µg.


Target Information

Apolipoprotein A-1 (ApoA-I) is the major protein component of high-density lipoprotein (HDL) in human plasma. The molecular mass is approximately 24 kDa. ApoA-I acts as a cofactor for enzymes involved in cholesterol metabolism and is primarily produced in the liver. Typical plasma concentration is 270–380 mg/100 mL.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.