
Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience
인간 HLA-A3 항원을 인식하는 단클론 항체로, NovaFluor Yellow 730 형광체로 결합되어 있습니다. 유세포 분석용으로 최적화되어 있으며 CellBlox Plus Blocking Buffer와 함께 제공됩니다. 고감도 형광 신호와 낮은 스필오버 특성을 제공합니다.
- 카탈로그번호
- H071T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience
Applications and Tested Dilution
- Application: Flow Cytometry
- Tested Dilution: 5 µL (0.6 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host/Isotype | Mouse / IgG2a, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | GAP.A3 |
| Conjugate | NovaFluor™ Yellow 730 |
| Excitation/Emission Max | 551/730 nm |
| Form | Liquid |
| Concentration | 0.6 µg/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098785 (AB_2937278) |
Available Formats
- APC
- FITC
- NovaFluor Blue 510
- NovaFluor Blue 585
- NovaFluor Blue 610-70S
- NovaFluor Blue 660-120S
- NovaFluor Blue 690
- NovaFluor Red 710
- NovaFluor Red 725
- NovaFluor Yellow 570
- NovaFluor Yellow 660
- NovaFluor Yellow 755
- PE
- Super Bright 436
- Super Bright 600
- Custom conjugation available
Product Specific Information
The monoclonal antibody GAP.A3 reacts with the human major histocompatibility complex (MHC) class I molecule HLA-A3, a member of the HLA-A family. HLA-A3 has two subtypes, HLA-A3.1 and HLA-A3.2, differing at amino acid positions 152 and 156. MHC class I molecules are expressed on all nucleated cells and present intracellular peptides to cytotoxic T lymphocytes.
HLA-A3 is expressed by 15–25% of cancer patients and binds the tumor-associated antigen human telomerase reverse transcriptase (hTERT).
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested for flow cytometry using normal human peripheral blood cells. Use 5 µL (0.6 µg) per test in a final volume of 100 µL. Recommended cell count: 10⁵–10⁸ cells/test.
Note:
NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI). Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for best results.
This product ships with CellBlox Plus Blocking Buffer (Cat. No. C001T06F01), which improves staining performance. Add 5 µL per sample to antibody cocktails before combining with cells. For single-color controls, use 5 µL per 100 µL of cell sample.
NovaFluor conjugates utilize Phiton™ technology, employing novel nucleic acid dye structures engineered for optimized fluorescence with minimized spectral spillover and spread.
Excitation: 552 nm; Emission: 718 nm; Laser: 561 nm (Yellow)
Target Information
HLA-A belongs to the HLA class I heavy chain paralogues. It forms a heterodimer with beta-2 microglobulin and is expressed on nearly all nucleated cells. The heavy chain (~45 kDa) has 8 exons encoding leader peptide, alpha domains, transmembrane region, and cytoplasmic tail. Polymorphisms in exons 2 and 3 determine peptide-binding specificity, crucial in transplantation compatibility and immunopeptidomics.
HLA and MHC antibodies are essential in Immunopeptidomics, aiding in neoantigen identification via LC-MS/MS.
For Research Use Only. Not for use in diagnostic procedures or resale without authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
