CacheBy
Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience
원본

Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience

상품 한눈에 보기

인간 HLA-A3를 인식하는 단클론 항체로, NovaFluor Yellow 730 형광체가 결합되어 있습니다. 유세포 분석용으로 최적화되었으며, CellBlox Plus Blocking Buffer와 함께 제공됩니다. 4°C 암소 보관, 동결 금지. 연구용 전용 제품입니다.

카탈로그번호
H071T0xxxx (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 02. 오후 12:26
Thermo Fisher Scientific H071T03Y07 HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
718,800원VAT 포함 790,680원
Thermo Fisher Scientific H071T02Y07 HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
337,000원VAT 포함 370,700원

Thermo Fisher Scientific · Thermo Fisher Scientific HLA-A3 Monoclonal Antibody (GAP.A3), NovaFluor Yellow 730, eBioscience

Applications

  • Flow Cytometry (Flow): 5 µL (0.6 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Mouse / IgG2a, kappa
Class Monoclonal
Type Antibody
Clone GAP.A3
Conjugate NovaFluor™ Yellow 730
Excitation / Emission Max 551 / 730 nm
Form Liquid
Concentration 0.6 µg/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3098785 (AB_2937278)

Additional Formats

  • APC
  • FITC
  • NovaFluor Blue 510
  • NovaFluor Blue 585
  • NovaFluor Blue 610-70S
  • NovaFluor Blue 660-120S
  • NovaFluor Blue 690
  • NovaFluor Red 710
  • NovaFluor Red 725
  • NovaFluor Yellow 570
  • NovaFluor Yellow 660
  • NovaFluor Yellow 755
  • PE
  • Super Bright 436
  • Super Bright 600
  • Custom conjugation available

Product Specific Information

Description:
The monoclonal antibody GAP.A3 reacts with the human major histocompatibility complex (MHC) class I molecule HLA-A3, a member of the HLA-A family. HLA-A3 has two subtypes (A3.1 and A3.2) differing at amino acid positions 152 and 156.
MHC class I molecules are expressed on all nucleated cells and present intracellular peptides to cytotoxic T lymphocytes. HLA-A3 is expressed by 15–25% of cancer patients and binds the tumor-associated antigen human telomerase reverse transcriptase (hTERT).

Each product includes:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested by flow cytometry using normal human peripheral blood cells.
Recommended usage: 5 µL (0.6 µg) per test in a final volume of 100 µL. Cell number: 10⁵–10⁸ cells/test.

Important Notes:

  • NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
  • Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assessment.
  • CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining.
    • Add 5 µL per sample before combining with cells.
    • For single-color controls: 5 µL per 100 µL of cell sample (10³–10⁸ cells).

Technology:
NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures designed to minimize spillover and spread.
Excitation: 552 nm; Emission: 718 nm; Laser: 561 nm (Yellow Laser).


Target Information

HLA-A belongs to the HLA class I heavy chain paralogues. This molecule is a heterodimer of a heavy chain and beta-2 microglobulin.

  • The heavy chain (~45 kDa) is membrane-anchored.
  • Plays a central role in immune response by presenting peptides derived from the ER lumen.
  • Expressed in nearly all cells.
  • Gene contains 8 exons:
    • Exon 1: leader peptide
    • Exons 2–3: α1, α2 domains (peptide binding)
    • Exon 4: α3 domain
    • Exon 5: transmembrane region
    • Exons 6–7: cytoplasmic tail
  • Polymorphisms in exons 2–3 determine peptide-binding specificity.
  • HLA typing is routinely performed for bone marrow and kidney transplantation.
  • HLA and MHC antibodies are crucial in Immunopeptidomics, aiding neoantigen identification via LC-MS/MS.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.