CacheBy
Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience
원본

Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience

상품 한눈에 보기

인간 CD4 항원 인식용 SK3 단클론 항체로, NovaFluor Blue 555 형광체가 결합된 제품입니다. Flow Cytometry 분석에 최적화되어 있으며, HIV 수용체 연구 및 T세포 서브세트 분석에 활용됩니다. CellBlox Plus Blocking Buffer 포함.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 11:05
Thermo Fisher Scientific H001T03B03 CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
777,400원VAT 포함 855,140원
Thermo Fisher Scientific H001T02B03 CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
341,600원VAT 포함 375,760원

Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience

Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), NovaFluor Blue 555, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 5 µL (0.1 µg)/test


Product Specifications

항목 내용
Species Reactivity Human
Host/Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Antibody
Clone SK3 (SK-3)
Conjugate NovaFluor™ Blue 555
Excitation/Emission Max 493/555 nm
Form Liquid
Concentration 2 µL/Test
Purification Affinity chromatography
Storage buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3097857 (AB_2896359)

Additional Formats Available

  • Alexa Fluor 532
  • Alexa Fluor 700
  • APC
  • APC-eFluor 780
  • Brilliant UV/Violet/Yellow series
  • NovaFluor Blue/Red variants
  • PE, PE-Cyanine5.5, PE-Cyanine7, PE-eFluor 610
  • PerCP-eFluor 710
  • Super Bright series
  • Custom conjugation available

Product Specific Information

Description:
The SK3 monoclonal antibody reacts with human CD4, a 59-kDa cell surface receptor expressed by thymocytes, mature T helper cells, and at low levels on monocytes. CD4 acts as a receptor for HIV, and SK3 blocks HIV binding and mixed lymphocyte reactions. SK3 and RPA-T4 recognize distinct epitopes.

Each product contains:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported:
Suitable for flow cytometric analysis.

Applications Tested:
Pre-titrated and validated for flow cytometric analysis of normal human peripheral blood cells. Recommended use: 5 µL (0.1 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).

NovaFluor Dyes Compatibility:
Not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI). Use Invitrogen LIVE/DEAD Fixable Dead Cell stains instead.

CellBlox Plus Blocking Buffer Usage:
Required for optimal staining with NovaFluor conjugates.
Add 5 µL per sample to antibody cocktails before combining with cells.
For single-color controls, use 5 µL per 100 µL cell sample (10³–10⁸ cells).

NovaFluor Technology:
Based on Phiton technology utilizing novel nucleic acid dye structures engineered for optimized fluorescent signatures and minimized spillover/spread.

Excitation: 496 nm
Emission: 555 nm
Laser: 488 nm (Blue)


Target Information

The CD4 antigen recognizes MHC class II molecules and acts as a co-receptor for HIV. Expressed mainly on T helper cells, monocytes, macrophages, and dendritic cells. Tissue expression includes thymus, lymph nodes, tonsils, spleen, and certain brain and gut regions. CD4 facilitates T-cell activation and may mediate neuronal damage in infectious and immune-mediated CNS diseases. Multiple alternatively spliced transcripts identified (RefSeq, July 2017).


For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.