F30800100 | VELP F30800100 EMA 502, Elemental Analyzer set | 재고문의 | set | 0원 | - | 0원 |
The all-in-one CHNS/O solution to broaden your analytical potential
EMA 502 Elemental Analyzer CHNS-O is the accurate and reliable solution for the determination of carbon, hydrogen, nitrogen, sulfur, and oxygen in various industrial sectors such as pharma and life science, organic chemistry, petrochemistry and energy, environmental, agronomy, food & feed.
CHNS-O analysis with EMA 502 Elemental Analyzer helps determine the structure of an unknown compound, as well as evaluate the structure and purity of a synthesized compound.
Working in accordance with official reference methods, EMA 502 performs CHNS determination as well as Oxygen determination in just a few minutes, without requiring any add-ons or additional external modules.
EMA 502 is a safe analyzer that does not require aggressive chemicals or time-consuming analysis steps.
Just set your next analysis and access a wealth of information from the sample!
Versatility and productivity with exclusive operating comfort
EMA 502 is engineered to work 24/7, 365 days a year unattended with fast and easy routine maintenance.
Processing up to 117 samples at a time, EMA 502 is extremely efficient and ensures the highest sample throughput thanks to the electronic autosampler and microbalance connection to the PC for direct weighing data transfer.
EMA 502 analyzes solid, semi-solid and liquid samples of up to 20 mg carbon content and minimizes operating costs thanks to VELP genuine consumables, carefully manufactured for the longest lifespan.
With just one powerful instrument and a quick configuration change, you will be able to successfully face multiple analytical challenges in elemental analysis.
Easily set and perform your CHNS analysis and then switch to O mode thanks to the exclusive connection panel!
Consistent performance, proven accuracy and tested reliability
EMA 502 is a flexible and robust analyzer, designed for superior reliability and premium accuracy.
The TCD detection technology ensures extremely accurate and reproducible results, with an RSD value of 0.2% (Sulphanilic acid).
Results are automatically calculated by the EMASoftTM software receiving real-time data from EMA 502 Elemental Analyzer.
Get a comprehensive understanding of the analysis output before even checking on the results thanks to the gas chromatographic column and TCD, which enable a real-time view of the analytical process and pathway with premium performance for the whole instrument life span.
EMA 502 Elemental Analyzer working principle
EMA 502 - CHNS Flowpath
The CHNS analysis starts with the combustion of the sample inside the VELP combustion furnace at a temperature higher than 1000°C to obtain elemental compounds.
VELP Vcopper™, a formulation of highly active copper powder, is placed in the lower part of the reactor to help the reduction of NOX into N2.
The flow then reaches the gas chromatographic column oven, which ensures homogenous and modular temperature leading to a complete separation of all the elements for the final detection by TCD.
When analyzing Oxygen, the sample undergoes pyrolysis inside the furnace and then passes through a chemical trap where all impurities are absorbed, before reaching the gas chromatographic column and the TCD for detection.
Unmatched ease-of-use and data security with EMASoft™ software
The EMASoft™ software is the powerful VELP solution that controls and operates the EMA 502 elemental analyzer.
EMASoft™ comes with a user-friendly interface that displays all the relevant information at a glance: results, database, and instrument working conditions.
It is possible to choose from a library of pre-installed methods and create customized ones. An easy calibration curve creation for all the elements allows for testing of any sample matrix with no memory effect.
- Start the analysis with few clicks
- Change the configuration in few steps with the animated gif tutorials
- Benefit from the real-time graph displaying gases detected by the TCD
- A dedicated maintenance menu sends alerts when the reactor is almost exhausted
- The result table shows the average, SD, and RSD of the analysis with direct selection on the graph
The EMA 502 software can be upgraded with the optional 21 CFR Part 11 Package for Pharmaceutical, Cosmetic and Food industry laboratories that require compliance with FDA regulation.
Ultimate support, maximized efficiency and improved workflow with VELP Ermes Cloud Platform
EMA 502 features the unique connection option to VELP Ermes Cloud Platform, the Smart Lab solution allowing you to reduce routine operations thanks to the real-time monitoring of your analyses wherever you are, at any time.
Just by using a PC, a Smartphone, or a Tablet you can manage multiple instruments, consumables, workflows, analysis data, and instrument working conditions.
Immediate event and alarm notifications inform you about analyses and the remote analysis interruption guarantees total control of your laboratory processes.
Grant access to instruments and data only to specific people in your organization and decide whether you like to share information directly with VELP or with authorized service centers to benefit from a reduced diagnostic time and enhanced service support resulting in the highest system uptime.
CHNS-O determination gets to a new level with VELP Ermes Cloud Platform.
TEMS™ Technology
Save Time, Energy, Money and Space
EMA 502 Elemental Analyzer CHNS-O works with the innovative TEMS™ benefits, for unmatched savings.
- Time Saving: rapid heating reduces wasted time
- Energy Saving: limited energy consumption thus cutting CO2 emissions
- Money Saving: cost reduction for each analysis
- Space Saving: the narrow footprint saves valuable laboratory bench space
TECHNICAL DATA
METHOD OF ANALYSIS | CHNS: Combustion O: Pyrolysis |
---|---|
ANALYSIS TIME | CHNS: from 12 minutes O: from 6 minutes |
DETECTOR | TCD (Thermal Conductivity Detector) |
SAMPLE WEIGHT | Up to 100mg (depending on C content) |
AUTOSAMPLER CAPACITY | up to 4 discs, 30 positions each (up to 117 samples) |
PRECISION | ≤ 0.2 % |
ANALYTICAL RANGE C | 0.001 – 20mg with Helium; 0.01 – 20mg with Argon |
ANALYTICAL RANGE H | 0.001 – 5mg with Helium; 0.01 – 5mg with Argon |
ANALYTICAL RANGE N | 0.001 – 20mg with Helium; 0.01 – 20mg with Argon |
ANALYTICAL RANGE S | 0.01 – 6mg with Helium |
ANALYTICAL RANGE O | 0.005 – 6 mg with Helium |
CARRIER GAS | Helium or Argon (Argon for CHN determination) |
COMBUSTION / PYROLYSIS TEMPERATURE | CHNS: 1030°C O: 1060°C |
CONNECTIVITY | USB; RS232 |
ERMES CONNECTION | Yes, via Wi-Fi or LAN connected to a PC |
21 CFR PART 11 COMPLIANCE | Yes, accessory |
POWER INPUT | 570 W |
DIMENSIONS (W X H X D) | 500 x 510 x 410 mm (H 680 mm with autosampler) 19.7 x 20.1 x 16.1 in (H 26.8 with autosampler) |
WEIGHT | 45 kg 99 lb |
Brochures & Leaflets
VELP Scientifica invites you to download brochures and leaflets in order to explore our premium quality solutions and to have all the major key arguments, features and specifications of a product in your hands, in any place, and at any time.
EMA 502 Elemental Analyzer CHNS-O Brochure [EN]
EMA 502 - How to connect to VELP Ermes
Analytical Instruments - Line Brochure [EN]
Product Portfolio - Brochure [EN]
Application notes
Choose among a comprehensive library of Application Notes / White Papers and learn more on how to optimize the performance of your VELP instruments. These documents offer typical analyses of well-known samples, together with official references and suggestions, to make you an expert!
CHNS Determination in nutraceutical products by flash combustion
CHNS Determination in reference soil samples
CHNS/O Determination in rubber samples – material characterization
CHNS-O Determination in pharmaceutical products by flash combustion
CS Determination in coal samples by flash combustion
EMA 502 - CHNS/O Determination in Metal Organic Frameworks by Flash Combustion
Certifications
Our compliance to statutory rules and regulations worldwide.
With the CE mark, VELP Scientifica declares that the products are designed and manufactured in compliance with the essential safety requirements of the European Directive on Safety.
The Certification Body (CB) Certificate is an international program created by the IECEE for the acceptance of product safety test results among participating laboratories and certification organizations around the world.
The cNEMKOus mark ensures this product is designed and manufactured in compliance with the International Directive on Safety IEC/EN 61010-1. The cNEMKOus mark has the same legal status as any other NRTL/SCC accredited marks, for U.S. and Canada.
CE Declaration of Conformity VELP Scientifica Elemental Analyzer EMA 502
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|