CacheBy
Thermo Fisher Scientific Mouse anti-Rat IgG2a Secondary Antibody, PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific Mouse anti-Rat IgG2a Secondary Antibody, PerCP-eFluor 710, eBioscience

상품 한눈에 보기

Flow cytometry용 Mouse anti-Rat IgG2a 2차 항체로 PerCP-eFluor 710 형광체 결합. Rat IgG2a에 특이적으로 결합하며 다른 isotype과 교차 반응 없음. 488 nm에서 여기, 710 nm에서 방출. 4°C에서 암소 보관.

카탈로그번호
46-4817-8x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 02. 오전 08:19
Thermo Fisher Scientific 46-4817-82 Mouse anti-Rat IgG2a Secondary Antibody, PerCP-eFluor 710, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
688,200원VAT 포함 757,020원
Thermo Fisher Scientific 46-4817-80 Mouse anti-Rat IgG2a Secondary Antibody, PerCP-eFluor 710, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
141,500원VAT 포함 155,650원

Thermo Fisher Scientific · Thermo Fisher Scientific Mouse anti-Rat IgG2a Secondary Antibody, PerCP-eFluor 710, eBioscience

Applications and Tested Dilution

  • Flow Cytometry (Flow): 0.06 µg/test

Product Specifications

항목 내용
Host / Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Secondary Antibody
Clone r2a-21B2
Conjugate PerCP-eFluor™ 710
Excitation / Emission Max 482 / 708 nm
Form Liquid
Concentration 0.2 mg/mL
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Wet ice
RRID AB_11042160
Target IgG2a
Antibody Form Whole Antibody

Available Formats

  • eFluor 570
  • eFluor 615
  • eFluor 660
  • FITC
  • PE
  • Custom conjugation available

Product Specific Information

The monoclonal antibody r2a-21B2 recognizes Rat IgG2a antibodies and serves as a secondary reagent in flow cytometry and microscopy. It does not cross-react with other rat isotypes or mouse antibodies.

  • Applications Reported: Flow cytometric analysis
  • Applications Tested: Tested by flow cytometry using mouse splenocytes stained with a rat IgG2a primary antibody
  • Recommended use: ≤ 0.06 µg per test (100 µL reaction volume, 10⁵–10⁸ cells/test)
  • Optimize antibody titration for best performance

Fluorochrome Information:
PerCP-eFluor® 710 can substitute for PE-Cy5, PE-Cy5.5, or PerCP-Cy5.5.

  • Excitation: 488 nm (blue laser)
  • Emission: 710 nm
  • Recommended filters: 685 LP dichroic mirror with 710/40 BP filter (695/40 BP acceptable)
  • Stable in samples fixed with freshly prepared 2% formaldehyde overnight at 4°C
  • Post-manufacturing filtered through 0.2 µm

Target Information

Anti-Rat secondary antibodies are affinity-purified with high specificity for rat immunoglobulins. They are useful for detection, sorting, or purification of target proteins. Secondary antibodies enhance versatility and sensitivity by enabling various detection systems (HRP, AP, fluorescence) and signal amplification. Typically, these antibodies are generated by immunizing host animals with pooled rat immunoglobulins and further purified or modified (e.g., immunoaffinity chromatography, fragmentation, or label conjugation).

For Research Use Only. Not for use in diagnostic procedures or resale without authorization.