CacheBy
Thermo Fisher Scientific Calsequestrin 2 Polyclonal Antibody
원본

Thermo Fisher Scientific Calsequestrin 2 Polyclonal Antibody

상품 한눈에 보기

Calsequestrin 2 단백질을 인식하는 Rabbit Polyclonal 항체로, Western blot과 IHC(P) 등 다양한 응용 가능. Human 및 Mouse 반응성, 항원 친화 크로마토그래피로 정제됨. 단기 4°C, 장기 -20°C 보관 권장.

카탈로그번호
PA521706
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 03. 오전 06:28
Thermo Fisher Scientific PA521706 Calsequestrin 2 Polyclonal Antibody 100 ul pk판매 단위 pk ·
재고 확인 필요
699,000원VAT 포함 768,900원

Thermo Fisher Scientific · Thermo Fisher Scientific Calsequestrin 2 Polyclonal Antibody

Applications

Application Tested Dilution
Western Blot (WB) 1:500–1:3,000
Immunohistochemistry (Paraffin) (IHC (P)) 1:100–1:1,000

Product Specifications

항목 내용
Species Reactivity Human, Mouse
Host/Isotype Rabbit / IgG
Class Polyclonal
Type Antibody
Immunogen Recombinant protein fragment containing a sequence corresponding to amino acids 124–388 (O14958) of Calsequestrin 2
Conjugate Unconjugated
Form Liquid
Concentration 0.68 mg/mL
Purification Antigen affinity chromatography
Storage buffer 0.1M Tris glycine, pH 7, with 10% glycerol
Contains 0.01% thimerosal
Storage conditions Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Shipping conditions Wet ice
RRID AB_11152287

Product Specific Information

  • Recommended positive control: HCT116
  • Predicted reactivity: Mouse (95%), Rat (96%), Dog (96%), Rabbit (96%), Chicken (90%), Bovine (95%)
  • Store product as a concentrated solution. Centrifuge briefly prior to opening the vial.

Target Information

Calsequestrin (CASQ) is a Ca²⁺-binding protein located primarily in the junctional sarcoplasmic reticulum of skeletal and cardiac muscle. The cardiac form (CASQ2) is encoded by a separate gene. CASQ2’s primary role is buffering sarcoplasmic reticulum Ca²⁺ ions, and it also regulates the open probability of ryanodine receptor 2 (RyR2).
Mutations in CASQ2 cause stress-induced polymorphic ventricular tachycardia (CPVT2), characterized by bidirectional ventricular tachycardia that may lead to cardiac arrest.

WARNING: This product can expose you to chemicals including mercury, which is known to the State of California to cause birth defects or other reproductive harm.
For more information, visit www.P65Warnings.ca.gov.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.