
Thermo Fisher Scientific CD162 (PSGL-1) Monoclonal Antibody (4RA10), PerCP-eFluor 710, eBioscience
마우스 CD162(PSGL-1)을 인식하는 4RA10 클론의 단클론 항체로, PerCP-eFluor 710으로 표지됨. 유세포분석에 적합하며 0.06 µg/test로 사용. 블루 레이저(488 nm)에서 여기되어 710 nm에서 방출. 면역세포 접착 및 이동 연구에 활용 가능.
- 카탈로그번호
- 46-1621-8x (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD162 (PSGL-1) Monoclonal Antibody (4RA10), PerCP-eFluor 710, eBioscience
Applications and Tested Dilution
| Application | Tested Dilution | Publications |
|---|---|---|
| Immunocytochemistry (ICC/IF) | - | View 1 publication |
| Flow Cytometry (Flow) | 0.06 µg/test | View 1 publication |
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Published Species | Not Applicable |
| Host / Isotype | Rat / IgG1, kappa |
| Recommended Isotype Control | Rat IgG1 kappa Isotype Control (eBRG1), PerCP-eFluor™ 710, eBioscience™ |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 4RA10 |
| Immunogen | Mouse PSGL-1 human IgG1 fusion protein |
| Conjugate | PerCP-eFluor™ 710 |
| Excitation/Emission Max | 482/708 nm |
| Form | Liquid |
| Concentration | 0.2 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE |
| Shipping Conditions | Ambient (domestic); Wet ice (international) |
| RRID | AB_2848336 |
Available Formats
- Unconjugated
- Alexa Fluor 488
- Alexa Fluor 647
- Functional Grade
- PE
- PE-eFluor 610
- Request custom conjugation
Product Specific Information
The 4RA10 monoclonal antibody reacts with mouse CD162 (P-selectin glycoprotein ligand-1, PSGL-1).
This clone is validated for flow cytometry and can block CD162 binding to CD62P and CD62L.
Applications Reported: Flow cytometric analysis
Applications Tested: Tested on mouse splenocytes at ≤0.06 µg/test (100 µL final volume).
Cell number may range from 10⁵–10⁸ cells/test. Titrate antibody for optimal performance.
Fluorophore Information:
PerCP-eFluor 710 emits at 710 nm and is excited with the blue laser (488 nm).
Recommended filter: 710/50 bandpass (695/40 acceptable alternative).
Ensure instrument compatibility.
Light Sensitivity: Tandem dye is sensitive to light; protect vial and samples from exposure.
Fixation:
Samples may be stored up to 3 days at 4°C in the dark using:
- IC Fixation Buffer (Product #00-8222-49)
- 1-step Fix/Lyse Solution (Product #00-5333-57)
Performance after fixation should be verified empirically.
Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Target Information
CD162 (PSGL-1) is a 120 kDa homodimeric protein expressed on leukocytes and platelets.
It binds CD62P (P-selectin), CD62L (L-selectin), and CD62E (E-selectin) to mediate leukocyte adhesion, rolling, and extravasation.
CD162 serves as an immune marker of T cell exhaustion in chronic viral infection and cancer.
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
