CacheBy
Thermo Fisher Scientific CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience
원본

Thermo Fisher Scientific CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience

상품 한눈에 보기

인간 CD127(IL-7 수용체 α)에 특이적인 단클론 항체로, eFluor 450 형광체로 표지되어 있음. Flow cytometry에 최적화되어 있으며, Violet laser(405 nm)로 여기됨. IL-7 신호전달 연구 및 T세포 조절 연구에 적합.

카탈로그번호
48-1278-4x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오후 02:58
Thermo Fisher Scientific 48-1278-42 CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
623,700원VAT 포함 686,070원
Thermo Fisher Scientific 48-1278-41 CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
322,600원VAT 포함 354,860원

Thermo Fisher Scientific · Thermo Fisher Scientific CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience

Thermo Fisher Scientific CD127 Monoclonal Antibody (eBioRDR5), eFluor 450, eBioscience

Applications and Tested Dilution

Application Tested Dilution Publications
Immunohistochemistry (IHC) - View 1 publication
Immunohistochemistry (Frozen) (IHC (F)) - View 1 publication
Flow Cytometry (Flow) 5 µL (0.125 µg)/test View 30 publications

Product Specifications

Item Description
Species Reactivity Human
Published Species Human, Rhesus monkey
Host / Isotype Mouse / IgG1, kappa
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), eFluor™ 450, eBioscience™
Class Monoclonal
Type Antibody
Clone eBioRDR5
Conjugate eFluor™ 450
Excitation / Emission Max 405 / 445 nm
Form Liquid
Concentration 5 µL/test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_1963567

Available Formats

  • Unconjugated
  • Alexa Fluor 488, 532, 561, 647, 700
  • APC, APC-eFluor 780
  • Biotin
  • Brilliant UV 496, 563, 737, 805
  • Brilliant Violet 421, 711, 786
  • eFluor 506, 660
  • FITC
  • Functional Grade
  • NovaFluor Blue, Red, UV, Violet, Yellow series
  • PE, PE-Cyanine5, 5.5, 7, PE-eFluor 610
  • PerCP-Cyanine5.5, PerCP-eFluor 710
  • Super Bright 436, 600, 645, 702, 780
  • Request custom conjugation

Product Specific Information

The eBioRDR5 monoclonal antibody reacts with human CD127 (Interleukin-7 Receptor alpha). CD127 forms a complex with CD132 (common gamma chain) to create the IL-7 receptor (IL-7R). This type I glycoprotein (~75–80 kDa) is expressed by immature B cells, thymocytes at various stages, and most mature T cells, with transient down-regulation upon activation.

IL-7 binding triggers signal transduction via tyrosine kinase pathways including Jak/STAT. IL-7 is essential for lymphocyte development and homeostatic proliferation of peripheral T cells. IL-7R signaling also regulates TCR locus rearrangement in γδ T cells.

CD127 expression is down-regulated on CD4⁺CD25⁺ regulatory T cells (Tregs). CD4⁺CD25⁺ cells with low CD127 expression are enriched for Foxp3⁺ Tregs, exhibiting higher suppressive activity in vitro.

Binding of eBioRDR5 to PBMCs is blocked by pre-incubation with recombinant human IL-7 (Product #14-1079-80).

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated for flow cytometry on normal human peripheral blood cells. Use at 5 µL (0.125 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).

Fluorophore Information:
eFluor® 450 is an alternative to Pacific Blue®. Excitation: 405 nm; Emission: 445 nm; Laser: Violet.
Filtered post-manufacturing (0.2 µm).


Target Information

CD127 (Interleukin-7 Receptor alpha, IL7R) is a glycoprotein regulating lymphopoiesis. The active IL7R is an alpha/gamma chain heterodimer. The gamma(c) chain activates signal transduction, while the alpha chain mediates specific signaling events. CD127 promotes proliferation of precursor B cells, thymocytes, T cell progenitors, and mature CD4⁺/CD8⁺ T cells. Dysfunctions are associated with severe combined immunodeficiency (SCID).


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.