
Norgen Escherichia coli (E.coli) O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes)
E. coli O157:H7의 STX1 및 STX2 유전자 기반 정량 DNA 표준으로 PCR 검출 및 정량화용 양성 대조군으로 사용 가능. 다중 방법으로 정량 확인된 고품질 DNA. Norgen TaqMan PCR 키트와 호환. -20°C 보관.
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Norgen · Norgen Escherichia coli (E.coli) O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes)
Norgen Escherichia coli (E.coli) O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes)
SKU: 28302
To be used as a positive control or PCR quantification standard for E. coli O157:H7.
Features and Benefits
- Quantified standard for use as a positive control or PCR quantification standard
- Vigorously quantified using multiple methods
- Includes partial sequence of STX-1 subunit A and STX-2 subunit A genes (refer to product insert for details)
- Compatible with E. coli O157:H7 TaqMan PCR Detection Kit and Probe/Primer Control Set
Product Description
E. coli O157:H7 is a rod-shaped, gram-negative bacterium known for producing Shiga-like toxins that can cause severe symptoms including hemorrhagic colitis and hemolytic uremic syndrome. Infection typically results from consumption of undercooked meat, untreated water, or raw milk.
Norgen’s Escherichia coli O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes) are cloned fragments of the Shiga-like toxin regions purified using Norgen’s sample preparation technology. They include partial sequences of STX-1 subunit A and STX-2 subunit A genes. The purified DNA is quantified using spectrophotometry, gel densitometry, and real-time PCR. Intended for use as positive controls or PCR quantification standards for E. coli O157:H7. Compatible with Norgen Biotek’s E. coli O157:H7 TaqMan PCR Detection Kit (Cat. TM41350) and Probe/Primer & Control Set (Cat. TM41310).
Specifications
| 항목 | 내용 |
|---|---|
| Volume Provided | 250 μL (STX1) 250 μL (STX2) |
| DNA Quantity | 2 × 10⁴ copies/μL |
| Storage Conditions | Store at -20°C or lower. Avoid multiple freeze-thaw cycles. Prepare aliquots if needed. |
Supporting Data
Figure 1. Escherichia coli (E.coli) O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes).
2 μL of Norgen’s E. coli O157:H7 Quantified Bacterial DNA Standards (STX1 and STX2 genes) and serial dilutions (colored curves) were used in a 20 μL E. coli O157:H7-specific PCR reaction using Norgen’s 2X PCR Master Mix (#28007). Using STX-1 and STX-2 specific TaqMan Primers/Probes, separate reactions were set up for STX1 and STX2 gene detection. Real-time PCR reactions were performed on a Bio-Rad CFX Real-Time PCR System. No-template controls with water were also tested (black curves). Consistent amplification was observed down to 20 copies/μL.
OCR 추출 그래프 정보
왼쪽 그래프 (STX1)
- 제목: Amplification STX1
- 샘플 농도: 40,000 copies / 400 copies / 40 copies
- 축 레이블: RFU (y축), Cycles (x축)
오른쪽 그래프 (STX2)
- 제목: Amplification STX2
- 샘플 농도: 40,000 copies / 400 copies / 40 copies
- 축 레이블: RFU (y축), Cycles (x축)
두 그래프 모두 동일한 구조를 가지며, PCR 증폭 곡선을 통해 STX1 및 STX2 유전자의 정량적 검출을 확인할 수 있습니다.
Documentation
제품 이미지

Norgen 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.



