CacheBy
Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience
원본

Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience

상품 한눈에 보기

인간 CD4 항원 인식용 SK3 단클론 항체로, PerCP-eFluor 710 형광체 결합 제품입니다. Flow Cytometry에 최적화되어 있으며 HIV 결합 차단 기능을 가집니다. Blue laser(488 nm)로 여기되어 710 nm에서 방출되며, 고감도 면역세포 분석에 적합합니다.

카탈로그번호
46-0047-4x (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오후 06:57
Thermo Fisher Scientific 46-0047-42 CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
662,800원VAT 포함 729,080원
Thermo Fisher Scientific 46-0047-41 CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
322,600원VAT 포함 354,860원

Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience

Thermo Fisher Scientific CD4 Monoclonal Antibody (SK3 (SK-3)), PerCP-eFluor 710, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 5 µL (0.06 µg)/test
Publications: View 12 publications


Product Specifications

항목 내용
Species Reactivity Human
Published Species Human, Mouse
Host / Isotype Mouse / IgG1, kappa
Recommended Isotype Control Mouse IgG1 kappa Isotype Control (P3.6.2.8.1), PerCP-eFluor™ 710, eBioscience™
Class Monoclonal
Type Antibody
Clone SK3 (SK-3)
Conjugate PerCP-eFluor™ 710
Excitation / Emission Max 482 / 708 nm
Form Liquid
Concentration 5 µL/Test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with 0.2% BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_1834402

Additional Formats Available

  • Alexa Fluor 532
  • Alexa Fluor 700
  • APC
  • APC-eFluor 780
  • Brilliant UV 395
  • Brilliant UV 496
  • Brilliant UV 563
  • Brilliant UV 737
  • Brilliant UV 805
  • Brilliant Violet 421
  • Brilliant Violet 605
  • eFluor 450
  • FITC
  • NovaFluor Blue Series (510–800)
  • NovaFluor Red Series (660–755)
  • NovaFluor UV 765
  • NovaFluor Violet Series (690–800)
  • NovaFluor Yellow Series (570–810)
  • PE, PE-Cyanine5.5, PE-Cyanine7, PE-eFluor 610
  • Super Bright Series (436–780)
  • Request custom conjugation

Product Specific Information

Description:
The SK3 monoclonal antibody reacts with human CD4, a 59-kDa cell surface receptor expressed by most thymocytes, a subset of mature T helper cells, and at low levels on monocytes. CD4 acts as a receptor for HIV; SK3 blocks HIV binding and mixed lymphocyte reaction. SK3 and RPA-T4 antibodies recognize distinct epitopes.

Applications Reported:
This antibody is validated for use in flow cytometric analysis.

Applications Tested:
Pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. Recommended usage: 5 µL (0.06 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).

Fluorochrome Information:
PerCP-eFluor® 710 emits at 710 nm and is excited by the blue laser (488 nm). Recommended filter: 710/50 bandpass (695/40 acceptable alternative). Ensure instrument compatibility.

Fixation:
Samples can be stored in IC Fixation Buffer (Product #00-8222-49) or 1-step Fix/Lyse Solution (Product #00-5333-54) for up to 3 days at 4°C in the dark with minimal impact on brightness and FRET efficiency.

Excitation: 488 nm
Emission: 710 nm
Laser: Blue Laser
Filtration: 0.2 µm post-manufacturing filtered


Target Information

CD4 antigen recognizes MHC class II molecules and acts as a co-receptor for HIV. It is primarily expressed in T helper lymphocytes but also found in monocytes, macrophages, and dendritic cells. CD4 is detected in thymus, lymph nodes, tonsils, spleen, and various non-lymphoid tissues. It contributes to early T-cell activation via association with the T-cell receptor complex and Lck kinase, and may mediate neuronal damage in infectious or immune-mediated CNS diseases. Multiple alternatively spliced transcripts have been identified (RefSeq, July 2017).


For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.