CacheBy
Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590, eBioscience
원본

Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590, eBioscience

상품 한눈에 보기

인간 CD45 모든 아이소폼을 인식하는 2D1 단클론 항체로, NovaFluor Yellow 590 형광체가 결합된 제품입니다. Flow cytometry 분석에 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 제공됩니다. 높은 신호 대비와 낮은 스펙트럼 간섭으로 다중 분석에 적합합니다.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 10:28
Thermo Fisher Scientific H005T03Y02 CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
801,600원VAT 포함 881,760원
Thermo Fisher Scientific H005T02Y02 CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
341,600원VAT 포함 375,760원

Thermo Fisher Scientific · Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590, eBioscience

Thermo Fisher Scientific CD45 Monoclonal Antibody (2D1), NovaFluor Yellow 590

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 5 µL (0.8 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host/Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Antibody
Clone 2D1
Conjugate NovaFluor™ Yellow 590
Excitation/Emission Max 563 / 594 nm
Form Liquid
Concentration 5 µL/test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
RRID AB_3098013 (AB_2896522)

Additional Available Formats

  • Alexa Fluor 700
  • APC
  • APC-eFluor 780
  • Brilliant Violet 711
  • eFluor 450
  • FITC
  • NovaFluor Blue / Red / Violet / Yellow series (multiple wavelengths)
  • PE, PE-Cyanine7, PE-eFluor 610
  • PerCP-Cyanine5.5
  • Super Bright 436, 600, 645, 780
  • Request custom conjugation available

Product Specific Information

The 2D1 monoclonal antibody reacts with all isoforms of human CD45 (Leukocyte Common Antigen, LCA), expressed by all hematopoietic cells except erythrocytes and platelets. CD45 possesses tyrosine phosphatase activity and plays a key role in lymphocyte activation.

Each product includes:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-diluted and validated for flow cytometry on normal human peripheral blood cells. Recommended usage: 5 µL (0.8 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).

Important Notes:

  • NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
  • Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assays.
  • CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining. Add 5 µL per sample before combining with cells.
  • For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).

NovaFluor conjugates utilize Phiton™ technology, engineered for optimized fluorescent signatures minimizing spillover and spread.

Excitation: 552 nm
Emission: 592 nm
Laser: 561 nm (Yellow)

Target Information

CD45 (LCA) is a receptor-type protein tyrosine phosphatase expressed on all nucleated hematopoietic cells, absent on non-hematopoietic tissues. It is critical for lymphocyte development and antigen signaling, regulating Src-family kinases and JAK kinases. CD45 isoforms differ by extracellular domain splicing and play roles in membrane localization, apoptosis, and immune regulation.

For Research Use Only. Not for use in diagnostic procedures or resale without authorization.

제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.