
Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 610-70S, eBioscience
인간 CD4 항원을 인식하는 OKT4 단클론 항체로, NovaFluor Blue 610-70S 형광체가 결합된 제품입니다. Flow cytometry에 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 제공됩니다. HIV 수용체 연구 및 T 세포 분석에 적합합니다.
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 610-70S, eBioscience
Thermo Fisher Scientific CD4 Monoclonal Antibody (OKT4 (OKT-4)), NovaFluor Blue 610-70S
Applications
- Flow Cytometry (Flow)
Tested Dilution: 5 µL (1.0 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host/Isotype | Mouse / IgG2b, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | OKT4 (OKT-4) |
| Conjugate | NovaFluor™ Blue 610-70S |
| Excitation/Emission Max | 492/616 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098400 (AB_2910772) |
Additional Formats
- Unconjugated
- Alexa Fluor 488
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- Brilliant UV 661
- Brilliant Violet 650
- Brilliant Violet 786
- eFluor 450
- eFluor 660
- FITC
- Functional Grade
- NovaFluor Blue 660-120S
- NovaFluor Blue 690
- NovaFluor Yellow 660
- PE
- PE-Cyanine7
- PerCP-Cyanine5.5
- Super Bright 436
- Super Bright 600
- Super Bright 702
- Request custom conjugation
Product Specific Information
The OKT4 monoclonal antibody reacts with human CD4, a 59 kDa cell surface glycoprotein expressed by thymocytes, T-helper cells, and at low levels on monocytes. CD4 is a receptor for HIV. The OKT4 antibody recognizes a different epitope than RPA-T4 and does not cross-block binding.
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Flow cytometric analysis of normal human peripheral blood cells. Recommended ≤5 µL (1.0 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).
Note:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains with NovaFluor dyes.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining. Add 5 µL per sample to antibody cocktails.
NovaFluor conjugates utilize Phiton technology with engineered fluorescent signatures minimizing spillover and spread.
Excitation: 509 nm
Emission: 614 nm
Laser: 488 nm (Blue)
Target Information
CD4 antigen recognizes MHC class II molecules and acts as a co-receptor for HIV. Expressed mainly in T-helper cells, monocytes, macrophages, and dendritic cells. Found in thymus, lymph nodes, tonsils, spleen, and other tissues. CD4 contributes to early T-cell activation and may mediate neuronal damage in immune-related CNS diseases. Multiple alternatively spliced transcripts identified (RefSeq, July 2017).
For Research Use Only. Not for use in diagnostic procedures.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
