CacheBy
Thermo Fisher Scientific HCN4 Monoclonal Antibody (N114/10), FITC
원본

Thermo Fisher Scientific HCN4 Monoclonal Antibody (N114/10), FITC

상품 한눈에 보기

HCN4 단백질을 검출하기 위한 FITC 결합 마우스 단클론 항체입니다. Western blot, IHC, ICC/IF, Flow cytometry 등 다양한 응용에 적합합니다. 인간, 마우스, 토끼, 랫트 반응성을 가지며, 고순도 Protein G 정제 및 형광 특성(498/517 nm)을 제공합니다.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 03:58
Thermo Fisher Scientific MA545432 HCN4 Monoclonal Antibody (N114/10), FITC 100 ug pk판매 단위 pk ·
재고 확인 필요
663,800원VAT 포함 730,180원

Thermo Fisher Scientific · Thermo Fisher Scientific HCN4 Monoclonal Antibody (N114/10), FITC

Thermo Fisher Scientific HCN4 Monoclonal Antibody (N114/10), FITC

Applications and Tested Dilutions

Application Tested Dilution
Western Blot (WB) 1:1,000
Immunohistochemistry (Paraffin) (IHC (P)) 1:1,000
Immunohistochemistry (PFA fixed) (IHC (PFA)) 1:1,000
Immunocytochemistry (ICC/IF) 1:100
Flow Cytometry (Flow) Assay-dependent
Antibody Microarray (AM) Assay-dependent

Product Specifications

Specification Description
Species Reactivity Human, Mouse, Rabbit, Rat
Host / Isotype Mouse / IgG1
Class Monoclonal
Type Antibody
Clone N114/10
Immunogen Fusion protein amino acids 1019–1198 (C-terminus) of rat HCN4
Conjugate FITC
Excitation / Emission Max 498 / 517 nm
Form Liquid
Concentration 1 mg/mL
Purification Protein G
Storage Buffer 9.09 mM sodium bicarbonate/PBS, pH 7.4, with 640.91 mM DMSO, 136.36 mM ethanolamine
Contains No preservative
Storage Conditions 4°C, store in dark
Shipping Conditions Ambient (domestic); Wet ice (international)
RRID AB_2931886

Additional Formats

Product Specific Information

1 µg/mL of MA5-45432 was sufficient for detection of HCN4 in 10 µg of COS cell lysate transiently transfected with HCN4 by colorimetric immunoblot analysis using Goat anti-mouse IgG:HRP as the secondary antibody. Detects approximately 130 kDa. No cross-reactivity against other HCNs.

Target Information

HCN4 is a member of the family of hyperpolarization-activated and cyclic-nucleotide-gated (HCN) channels. HCN currents are linked to pacemaker activity in the heart and brain, resting potential control, and neuronal plasticity. HCN4 channels also function as receptors for sour taste and are associated with pacemaker potential generation in the sinoatrial node.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

제품 이미지

Spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.