CacheBy
Thermo Fisher Scientific CD45 Monoclonal Antibody (30-F11), NovaFluor Red 710, eBioscience
원본

Thermo Fisher Scientific CD45 Monoclonal Antibody (30-F11), NovaFluor Red 710, eBioscience

상품 한눈에 보기

Mouse CD45 검출용 Rat IgG2b 단클론 항체로, NovaFluor Red 710 형광체가 결합되어 Flow Cytometry에 최적화됨. 모든 혈액세포 표면 CD45 동형체 인식. CellBlox Plus Blocking Buffer 포함으로 NovaFluor 염료 사용 시 최적 성능 제공. 연구용 전용 제품.

카탈로그번호
M005T02R04
판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 01. 오후 06:23
Thermo Fisher Scientific M005T02R04 CD45 Monoclonal Antibody (30-F11), NovaFluor Red 710, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
370,300원VAT 포함 407,330원

Thermo Fisher Scientific · Thermo Fisher Scientific CD45 Monoclonal Antibody (30-F11), NovaFluor Red 710, eBioscience

Thermo Fisher Scientific CD45 Monoclonal Antibody (30-F11), NovaFluor Red 710, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 0.4 µg/test


Product Specifications

항목 내용
Species Reactivity Mouse
Host/Isotype Rat / IgG2b, kappa
Class Monoclonal
Type Antibody
Clone 30-F11
Conjugate NovaFluor™ Red 710
Excitation/Emission Max 637 / 713 nm
Form Liquid
Concentration 0.1 mg/mL
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2, with BSA
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3098937 (AB_2896770)

Additional Formats Available

  • Unconjugated
  • Alexa Fluor 488, 532, 561, 660, 700
  • APC, APC-eFluor 780
  • Biotin
  • Brilliant UV/Violet/Yellow series
  • PE, PE-Cyanine variants
  • PerCP-Cyanine5.5
  • Super Bright series
  • NovaFluor Blue, Red, Violet, Yellow series
  • Custom conjugation available

Product Specific Information

Description:
The 30-F11 monoclonal antibody reacts with all isoforms of mouse CD45 (Leukocyte Common Antigen, LCA). CD45 is expressed by all hematopoietic cells excluding mature erythrocytes and platelets. It plays a crucial role in lymphocyte activation through its tyrosine phosphatase enzymatic activity.

Each product contains:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported:
Suitable for flow cytometric analysis.

Applications Tested:
Validated for flow cytometric analysis of mouse bone marrow cells at ≤0.4 µg/test.
A test is defined as staining a cell sample in 100 µL final volume (10⁵–10⁸ cells/test).
Antibody titration is recommended for optimal performance.

NovaFluor Compatibility:
NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., PI, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assays.

CellBlox Plus Blocking Buffer:
Required for optimal staining with NovaFluor conjugates.
Add 5 µL per sample before combining with cells.
For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).

Technology:
NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures minimizing spillover and spread.

Excitation/Emission:
Excitation: 639 nm
Emission: 710 nm
Laser: 633–640 nm (Red)


Target Information

CD45 (LCA, leukocyte common antigen) is a receptor-type protein tyrosine phosphatase expressed in all nucleated hematopoietic cells (~10% of lymphocyte surface proteins).
It regulates Src-family kinases, T/B-cell antigen receptor signaling, and cytokine receptor signaling.
CD45 isoforms arise via alternative splicing and differ in extracellular domains.
It also modulates integrin-mediated signaling, apoptosis, and immune functions.


For Research Use Only. Not for use in diagnostic procedures. Not for resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.