Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 730, eBioscience
Mouse VISTA 단백질을 인식하는 MIH64 단클론 항체로 NovaFluor Yellow 730 형광체가 결합된 제품. Flow Cytometry에 최적화되어 있으며, CellBlox Plus Blocking Buffer 포함. 4°C 보관, 고정 및 비고정 세포 모두에 사용 가능.
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 730, eBioscience
Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 730, eBioscience
Applications
- Flow Cytometry (Flow)
Tested Dilution: 0.4 µg/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Host/Isotype | Rat / IgG2a, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | MIH64 |
| Conjugate | NovaFluor™ Yellow 730 |
| Excitation/Emission Max | 551 / 730 nm |
| Form | Liquid |
| Concentration | 0.1 mg/mL |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3099102 (AB_2926227) |
Additional Conjugate Formats
- APC
- Brilliant UV 615
- Brilliant UV 737
- NovaFluor Blue 660-120S
- NovaFluor Yellow 610
- PE
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Request custom conjugation available
Product Specific Information
This MIH64 monoclonal antibody recognizes mouse VISTA (B7-H5 or PD-H1).
It is suitable for flow cytometry on both native and paraformaldehyde-fixed cells.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Flow cytometric analysis of mouse splenocytes at ≤ 0.4 µg/test (100 µL final volume).
Cell number should be empirically determined (10⁵–10⁸ cells/test).
Careful titration is recommended for optimal performance.
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability detection.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining with NovaFluor conjugates.
- Add 5 µL per sample, regardless of the number of NovaFluors used.
- For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).
NovaFluor conjugates utilize Phiton™ technology, based on nucleic acid dye structures engineered to minimize spillover and spread.
Excitation: 552 nm; Emission: 718 nm; Laser: 561 nm (Yellow)
Note: Internal testing shows NovaFluor Yellow 730 may stain B cells non-specifically in SJL mice.
No non-specific staining observed in BALB/c or C57BL/6 strains. Other strains not tested.
Target Information
VISTA (V-domain Ig containing suppressor of T-cell activation), also known as B7-H5 or PD-1H, is encoded by the VSIR gene.
It shares homology with PD-L1 but exhibits distinct expression patterns.
In both mouse and humans, VISTA is predominantly expressed on hematopoietic cells—highest on myeloid cells, lower on T cells, and typically absent on B cells.
VISTA expressed by antigen-presenting cells suppresses CD4 and CD8 T-cell proliferation and cytokine production, making it a potential target for cancer immunotherapy.
Reported ligands include CD28H, VSIG-3, and VSIG-8.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.