Thermo Fisher Scientific TaqMan MicroRNA Cells-to-CT Kit

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
4391848-Thermo Fisher Scientific 4391848 TaqMan MicroRNA Cells-to-CT Kit Each pk재고문의pk3,121,000-3,433,100

Invitrogen™

TaqMan™ MicroRNA Cells-to-CT™ Kit

Green features

The Ambion™ TaqMan™ MicroRNA Cells-to-CT™ Kit makes it possible to perform microRNA (miRNA) expression profiling directly from cultured cells without자세히 알아보기

The Ambion™ TaqMan™ MicroRNA Cells-to-CT™ Kit makes it possible to perform microRNA (miRNA) expression profiling directly from cultured cells without RNA purification. The kit is the first to offer a simple, complete workflow for miRNA expression analysis from a few samples, or it can easily be incorporated into automated, high throughput applications.

• Complete, validated solution—Optimized workflow includes cell lysis reagents, DNase, TaqMan™ MicroRNA RT reagents, and TaqMan™ Universal PCR Master Mix
• Fast, simple, and convenient—Prepare samples in 10 minutes; eliminate tedious RNA isolation
• Gold standard specificity—Achieve superior results with TaqMan™ MicroRNA reagents
• Robust performance—Results equivalent to purified RNA
• Broad input dynamic range—Linear detection from 10 to 100,000 cells

Complete, Validated Solution

Featuring a unique method for lysing cultured cells while removing genomic DNA and preserving RNA integrity, the TaqMan™ MicroRNA Cells-to-CT™ Kit contains TaqMan™ MicroRNA reverse transcription (RT) reagents and TaqMan™ Universal PCR Master Mix for real-time PCR analysis. The TaqMan™ MicroRNA Cells-to-CT™ Kit has been extensively tested and validated with TaqMan™ MicroRNA Assays, sold separately.

Simple, Convenient 10-Minute Sample Preparation

The TaqMan™ MicroRNA Cells-to-CT™ Kit incorporates a simple 10-minute sample preparation procedure (Figure 1) for use with 10–100,000 cultured cells⁄sample, either in plates or tubes. Cells are washed in PBS and lysed for 8 minutes at room temperature; DNase treatment can be performed concurrently. Lysis is terminated at room temperature by a 2-minute incubation with Stop Solution.

The TaqMan™ MicroRNA Cells-to-CT™ Kit lysates are now ready for reverse transcription or can be stored at -20°C for up to 5 months. Since samples are not subjected to an RNA purification process, all of the small RNA species are available for analysis. Because samples can be processed directly in culture plates (96 or 384 wells), sample handling is reduced, and the risk of sample loss or transfer error is minimized. No heating, washing, or centrifugation is required; the kit greatly simplifies a traditionally time-consuming, labor intensive process and reduces it to 10 minutes.

Gold Standard Specificity—Superior Results with TaqMan™ MicroRNA Reagents

Applied Biosystems has developed a state-of-the-art solution to the fundamental problem associated with the short length of mature miRNAs. TaqMan™ MicroRNA Assays (sold separately) include a unique, target-specific stem-loop reverse-transcription primer (Figure 2). The stem-loop structure is designed to incorporate specificity for the targeted mature miRNA, in contrast to other methods that indiscriminately extend and prime all RNA in a sample. The TaqMan™ MicroRNA RT reagents, included in the TaqMan™ MicroRNA Cells-to-CT™ Kit, were specifically designed to work in conjunction with this innovative assay design.

The ability to distinguish between highly homologous mature miRNA targets is required for accurate miRNA expression analysis. The TaqMan™ MicroRNA Cells-to-CT™ Kit, in conjunction with the TaqMan™ MicroRNA Assays, delivers the specificity needed to distinguish between highly homologous targets, as seen in Figure 3. In this example, lysates from the TaqMan™ MicroRNA Cells-to-CT™ Kit or purified miRNA were used in real-time PCR using TaqMan™ MicroRNA Assays to detect single base differences on exogenously added miRNA templates. Specificity obtained with TaqMan™ MicroRNA Cells-to-CT™ Kit lysates (Figure 3A) was equivalent to that using purified RNA (Figure 3B).

Robust Performance—Results Equivalent to Purified RNA

This new kit has been extensively tested with a broad selection of TaqMan™ MicroRNA Assays and demonstrates performance equivalent to that obtained with purified RNA (Figure 4). The TaqMan™ MicroRNA Cells-to-CT™ Kit workflow enables unsurpassed miRNA expression evaluation with > 900 available TaqMan™ MicroRNA Assays.

Broad Input Dynamic Range—Linear Detection from 10 to 100,000 Cells

Because miRNA expression levels can vary widely due to sample type, developmental stage, or disease progression, it is important to have sensitive tools for miRNA expression analysis. Now, miRNA targets that vary from a few copies to millions of copies can be accurately quantitated in the same experiment.

The TaqMan™ MicroRNA Cells-to-CT™ Kit works robustly with as few as 10 cells, and up to 100,000 cells. Furthermore, to maximize sensitivity, the TaqMan™ MicroRNA Cells-to-CT™ Kit allows up to 33% of the RT reaction volume to be comprised of sample lysate (singleplex RT). Figure 5 demonstrates the linearity and sensitivity of detection from TaqMan™ MicroRNA Cells-to-CT™ Kit lysates across 5 logs of cellular input per lysis reaction; results were equivalent to purified RNA. Additionally, the broad dynamic range of TaqMan™ MicroRNA Assays is not compromised by TaqMan™ MicroRNA Cells-to-CT™ Kit lysates (data not shown).

Proven Performance, Proven Together

All components of the TaqMan™ MicroRNA Cells-to-CT™ Kit have been optimized for consistent and reliable performance. This removes the guesswork involved in assembling separate kits for sample preparation, reverse transcription, and real-time PCR. The TaqMan™ MicroRNA Cells-to-CT™ Kit has been validated with TaqMan™ MicroRNA Assays for added quality assurance.

사양

검출 방법Primer-probe

형식Tube

GC-Rich PCR PerformanceHigh

PCR 방법2-step RT-qPCR

중합효소DNA Polymerase

반응 속도Standard

용도(장비)7000 System, 7300 System, 7500 System, 7900HT System,Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system

그린 기능Fewer resources used and less waste, Less hazardous

패시브 참조 염료ROX (Pre-mixed)

제품라인Ambion™, Cells-to-CT™, TaqMan™

제품 유형MicroRNA Cells-to-C Kit

수량100 reactions

역전사 효소M-MLV

배송 조건Dry Ice

충분100 Reactions

용도(애플리케이션)miRNA analysis

반응 수100 Reactions

샘플 종류Cell

Unit SizeEach


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0