Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Red 755, eBioscience
마우스 CD48 항원을 인식하는 HM48-1 단클론 항체로, NovaFluor Red 755 형광체가 결합되어 있습니다. Flow Cytometry에 최적화되어 있으며, CellBlox Plus Blocking Buffer가 포함됩니다. CD48/CD2 및 CD48/CD244 상호작용 억제 연구에 적합합니다.
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Applications
- Flow Cytometry (Flow)
Tested Dilution: 0.2 µg/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Mouse |
| Host/Isotype | Armenian hamster / IgG |
| Class | Monoclonal |
| Type | Antibody |
| Clone | HM48-1 |
| Conjugate | NovaFluor™ Red 755 |
| Excitation/Emission Max | 636/755 nm |
| Form | Liquid |
| Concentration | 0.1 mg/mL |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE |
| RRID | AB_3099071 (AB_2926196) |
Additional Formats Available
- Alexa Fluor 700
- APC
- APC-eFluor 780
- Biotin
- eFluor 450
- FITC
- NovaFluor Blue 660-120S
- NovaFluor Blue 690
- NovaFluor Red 685
- NovaFluor Red 725
- NovaFluor Yellow 610
- NovaFluor Yellow 700
- NovaFluor Yellow 730
- NovaFluor Yellow 755
- PE
- PE-Cyanine7
- PE-eFluor 610
- PerCP-eFluor 710
- Super Bright 600
- Super Bright 702
- Request custom conjugation
Product Specific Information
The HM48-1 monoclonal antibody reacts with mouse CD48 antigen (also known as BCM1, Blast-1 in human, and OX-45 in rat).
CD48 is a 45 kDa GPI-linked glycoprotein of the SLAM family, expressed on most hematopoietic cells. It serves as a useful marker for identifying hematopoietic progenitor populations, including HSCs (CD150⁺CD244⁻CD48⁻), MPPs (CD244⁺CD150⁻CD48⁻), and restricted progenitors (CD48⁺CD244⁺CD150⁻).
CD48 plays a critical role in adhesion and T cell activation. In mice, its primary counter-receptors are CD2 and CD244. HM48-1 modulates CD48 functions in vitro and in vivo, including:
- Blocking CD48/CD2 and CD48/CD244 interactions
- Inhibiting mitogen-activated spleen cell proliferation
- Providing costimulation for TCR-activated T cells
- Prolonging cardiac allograft survival in vivo
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Flow cytometric analysis of mouse splenocytes (≤0.2 µg/test).
A test corresponds to staining a cell sample in a final volume of 100 µL (10⁵–10⁸ cells/test). Antibody titration is recommended for optimal performance.
Important Note:
NovaFluor dyes are incompatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assessment.
CellBlox Plus Blocking Buffer (Cat. No. C001T06F01)
Required for optimal staining with NovaFluor conjugates.
Add 5 µL per sample (regardless of number of NovaFluors).
For single-color controls: 5 µL per 100 µL cell sample (10³–10⁸ cells).
NovaFluor Conjugates
Based on Phiton™ technology using novel nucleic acid dye structures for engineered fluorescent signatures optimized for minimal spillover and spread.
Excitation: 636 nm
Emission: 756 nm
Recommended Laser: 633–640 nm (Red)
Target Information
CD48 (Blast-1) belongs to the CD2 subset of the Ig superfamily (CD2, CD58, CD84, CD150, CD229, CD244, etc.).
It mediates homotypic and heterotypic adhesion through interactions with other Ig family members.
CD48 is GPI-anchored and broadly expressed on hematopoietic cells, serving as:
- High-affinity ligand for 2B4
- Low-affinity ligand for CD2
The 2B4-CD48 interaction regulates NK and NK-T cell proliferation. CD48 signaling activates eosinophils and is upregulated in infectious diseases.
Expression pattern:
- Strong: lymphocytes, monocytes
- Weak: granulocytes
- Absent: platelets, fibroblasts, epithelium, endothelium
CD48 is a marker for detecting GPI anchoring defects (e.g., paroxysmal nocturnal hemoglobulinuria, PNH) and may be involved in allergic airway disease pathology, offering potential pharmacological targets for conditions such as allergic rhinitis and asthma.
For Research Use Only.
Not for use in diagnostic procedures or resale without authorization.
제품 이미지

🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Red 725, eBioscience
767,400원

Thermo Fisher Scientific
Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Red 685, eBioscience
304,800원

Thermo Fisher Scientific
Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Red 755, eBioscience
643,200원

Thermo Fisher Scientific
Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Blue 690, eBioscience
304,800원

Thermo Fisher Scientific
Thermo Fisher Scientific CD48 Monoclonal Antibody (HM48-1), NovaFluor Red 685, eBioscience
914,000원
배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|