Thermo Fisher Scientific CD42b Monoclonal Antibody (HIP1), NovaFluor Blue 610-70S, eBioscience
인간 CD42b를 인식하는 HIP1 단클론 항체로, NovaFluor Blue 610-70S 형광체가 결합된 유세포분석용 항체입니다. CellBlox Plus Blocking Buffer와 함께 제공되며, 488 nm 레이저에서 최적 성능을 발휘합니다. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- H051T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD42b Monoclonal Antibody (HIP1), NovaFluor Blue 610-70S, eBioscience
Applications and Tested Dilution
- Application: Flow Cytometry (Flow)
- Tested Dilution: 5 µL (0.2 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | HIP1 |
| Conjugate | NovaFluor™ Blue 610-70S |
| Excitation / Emission Max | 492 / 616 nm |
| Form | Liquid |
| Concentration | 0.2 µg/test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098609 (AB_2925994) |
Additional Available Formats
- Unconjugated
- APC
- FITC
- NovaFluor Blue 510
- NovaFluor Blue 660-120S
- NovaFluor Yellow 610
- PE
- PE-Cyanine7
- PerCP-eFluor 710
- Super Bright 436
- Super Bright 600
- Super Bright 702
- Custom conjugation available
Product Specific Information
The HIP1 monoclonal antibody reacts with the human CD42b molecule, a 135 kDa transmembrane protein also known as platelet gpIb.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and tested for flow cytometric analysis of human platelets.
Recommended use: 5 µL (0.5 µg) per test in a total volume of 100 µL. Cell number: 10⁵–10⁸ cells/test.
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for compatibility.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) is required for optimal staining with NovaFluor conjugates.
- Add 5 µL of CellBlox Plus per sample before combining with cells.
- For single-color controls, use 5 µL per 100 µL of cell sample (10³–10⁸ cells).
NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures designed to minimize spillover and spread impacts.
Excitation: 509 nm
Emission: 614 nm
Laser: 488 nm (Blue)
Target Information
CD42b is a platelet activation marker involved in coagulation and platelet aggregation. It interacts with extracellular matrix and adhesion molecules and forms part of the GPIb-IX-V receptor complex critical for platelet-rich thrombus formation. CD42b binds von Willebrand factor (VWF), thrombin, coagulation factors XI and XII, high molecular weight kininogen, TSP-1, integrin Mac-1, and P-selectin. It is expressed on platelets and megakaryocytes in bone marrow. Mutations in CD42b are associated with Bernard-Soulier syndrome and platelet-type von Willebrand disease.
For Research Use Only. Not for use in diagnostic procedures.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.