😃 아래 영상 참고하세요^^

Reactor-Ready Duo Lab Reactor

Reactor-Ready Duo shares the same unique features as Reactor-Ready but holds two independent jacketed glass reaction vessels. The system can be configured to operate with a single thermoregulator controlling the jacket temperature of both vessels simultaneously; or with two thermoregulators controlling the temperature of each vessel independently.

  • Interchangeable

    Rapid exchange of both vessels independently, with quick-release vessel clamp and hose couplings.

  • Flexible

    Choice of manifold kits allow two vessels to run from a single thermoregulator or two separate thermoregulators.

  • Parallel or series

    System accepts two overhead stirrers which can be operated independently.

  • Take control

    Use optional Control Software to control fluid transfer between vessels.

Applications

Duo Icon

Parallel synthesis or reaction optimisation

Use similar or different size vessels and vary stirring speed, stirrer shape and temperature between vessels

2 part reaction icon

Two stage reaction

Transfer reactant from one vessel to the other using vacuum or a pump

Duo Single Reaction

Single reaction vessel

Using the second vessel as either a receiving or feed vessel (where reagents can be pre-heated or pre-cooled prior to addition)

Book an online demo

...it allows us to run reactions in parallel, whereby we use a single circulator to deliver the same temperature to adjacent vessels, allowing us to easily vary other key experimental parameters.Associate Professor, Stefan Bon, Department of Chemistry, University of Warwick

Thermofluid Manifolds

  • Choice of two manifolds kits
  • Single circulator manifolds
  • Double circulator manifolds

Vessels

  • 100ml to 5 litres
  • Combine different volumes
  • Vacuum jacketed options
  • Process and standard geometry

Unique Vessel Clamp

  • Supports two vessels
  • Change vessels independently
  • Change vessels in minutes

Simple Stirrer Alignment

  • Set and lock
  • Independent stirring for each vessel

Patented Stirrer Coupling

  • Drop in
  • No tools
  • No fuss

Hose Couplings

  • Quick-release
  • Connect in seconds
  • Chemical-resistant PEEK

Strong Framework

  • Heavy duty base
  • Solid s/steel support rods
  • Large drip tray

Reactor-Ready Duo Base System

RR121300 Reactor-Ready Duo Core

Double Circulator Manifold and Hose Kit

The double circulator kit is designed to work with two separate thermoregulators controlling the temperature of each vessel independently. With this set-up both vessels can operate at different temperatures.

RR121310 comprises:

  • R/H Upper Return Manifold with Vent Valve
  • L/H Upper Return Manifold with Vent Valve
  • R/H Lower Supply Manifold with Drain Valve
  • L/H Lower Supply Manifold with Drain Valve
  • 4 x Quick-Release Insulated Hoses, 60cm
  • 4 x Sealing Caps for Hoses

Single Circulator Manifold and Hose Kit

This single circulator kit is designed to work with one thermoregulator controlling the temperature of both vessels simultaneously. With this set-up both vessels would operate at the same temperature. The manifolds are supplied with a blanking plug should you wish to run only one vessel.

RR121305 comprises:

  • Central Upper Return Manifold with Vent Valve
  • Central Lower Supply Manifold with Drain Valve
  • 4 x Quick-Release Insulated Hoses, 70cm
  • 4 x Sealing Caps for Hoses
  • 2 x Stainless steel blanking plugs

    The range


Reactor-Ready Duo Manifold + Hose Kits

  • RR121119 Central Upper Return Manifold with Vent Valve – NW12
  • RR121120 Central Lower Supply Manifold with Drain Valve – NW12
  • RR121114 Quick-Release Insulated Hose 70cm HT Vessel-to-Manifold
  • RR121114 Quick-Release Insulated Hose 70cm HT Vessel-to-Manifold
  • RR121114 Quick-Release Insulated Hose 70cm HT Vessel-to-Manifold
  • RR121114 Quick-Release Insulated Hose 70cm HT Vessel-to-Manifold
  • RR121115 R/H Upper Return Manifold with Vent Valve – NW12
  • RR121116 R/H Lower Supply Manifold with Drain Valve – NW12
  • RR121117 L/H Upper Return Manifold with Vent Valve – NW12
  • RR121118 L/H Lower Supply Manifold with Drain Valve – NW12
  • RR121130 Quick Release Insulated Hose 60cm HT Vessel-to-Manifold – NW12
  • RR121130 Quick Release Insulated Hose 60cm HT Vessel-to-Manifold – NW12
  • RR121130 Quick Release Insulated Hose 60cm HT Vessel-to-Manifold – NW12
  • RR121130 Quick Release Insulated Hose 60cm HT Vessel-to-Manifold – NW12

Click to download these resources

[

Reactor-ready-Lab-Reactors

Reactor-Ready Lab Reactors Leaflet

](https://www.radleys.com/resources/reactor-ready-lab-reactors/)[Read more](https://www.radleys.com/resources/reactor-ready-lab-reactors/)

[

International Product Guide

Radleys International Product Guide

](https://www.radleys.com/resources/radleys-international-product-guide/)[Read more](https://www.radleys.com/resources/radleys-international-product-guide/)

[

Reactor-Ready Duo Instructions

Reactor-Ready Duo Instructions

](https://www.radleys.com/resources/reactor-ready-duo-instructions/)[Read more](https://www.radleys.com/resources/reactor-ready-duo-instructions/)

Case studies

Royochem Reactor-Ready Duo with AVA

AVA Lab Control Software with Reactor-Ready Duo improves new product development

Sun Chemicals CS1026 Reactor Ready Duo and Lab control software

High torque application for Reactor-Ready Duo and lab control software

University of Warwick CS1006 RRD

Reactor-Ready Duo increases synthesis productivity

Roal, Finland Choose Reactor-Ready Duo for their formulation chemistry

Roal, leading enzyme manufacturer, choose Reactor-Ready Duo for their formulation chemistry

Lanzhou Institute Reactor-Ready Duo

Safer, highly efficient experiments with Reactor-Ready Duo

Blog posts

AVA Lab Control Software

AVA Lab Control Software: A buyer’s guide

Read more

Reactor Ready Duo

Reactor-Ready Duo Core and Components

Easy-to-order Reactor-Ready Duo Core system includes all the framework components required for operation

Core Features include:

  • Robust heavy-duty framework features solid stainless steel support rods
  • Two separate quick release clamps support each of the vessels independently
  • Large drip tray will retain vessel contents
  • Manifold & Hose kits must be ordered separately

Reactor Ready Duo

RR121300 Core System includes

  • Duo stand with base, drip tray, support rods, bosses and all clamps
  • 4 x Hose tidies
  • 2 x PTFE Stirrer guides and couplings
  • 2 x Glass reaction vessel lids including sealing caps 1 x B19, 2 x B24, 1 x B29, 1 x B34
  • 2 x Vessel FEP O-ring seals and PTFE centering collars
  • 2 x Stainless steel vessel support collars

Reactor Ready Duo

Reactor-Ready Duo Manifolds & Hoses

A choice of manifold kits for use with one or two thermoregulators (circulators)

Reactor Ready Duo

RR121310 Double Circulator Manifold and Hose Kit

The double circulator kit is designed to work with two separate thermoregulators controlling the temperature of each vessel independently. With this set-up both vessels can operate at different temperatures.

  • R/H Upper Return Manifold with Vent Valve
  • L/H Upper Return Manifold with Vent Valve
  • R/H Lower Supply Manifold with Drain Valve
  • L/H Lower Supply Manifold with Drain Valve
  • 4 x Quick-Release Insulated Hoses, 60cm
  • 4 x Sealing Caps for Hoses

Reaction-Ready Duo

RR121305 Single Circulator Manifold and Hose Kit

This single circulator kit is designed to work with one thermoregulator controlling the temperature of both vessels simultaneously. With this set-up both vessels would operate at the same temperature. The manifolds are supplied with a blanking plug should you wish to run only one vessel.

  • Central Upper Return Manifold with Vent Valve
  • Central Lower Supply Manifold with Drain Valve
  • 4 x Quick-Release Insulated Hoses, 70cm
  • 4 x Sealing Caps for Hoses
  • 2 x Stainless steel blanking plugs

Reactor Ready Duo

How to order Reactor-Ready Duo

  1. Select the Reactor-Ready Duo Core: RR121300
  2. Choose Manifold and Hose kit for one or two circulators
  3. Choose the Vessel Kit or Kits you require by selecting the vessel volume and style
  4. Select the overhead stirrers you need
  5. If you need a thermoregulator, hoses, hose adapters, thermofluid or accessory glassware, then select from the accessory list
  6. If you need automation add AVA Software and Data Hub

Explore the range

[

Reactor-Ready vessels and accessories

Reactor-Ready Reaction Vessels & Accessories

](https://www.radleys.com/range/reactor-ready-reaction-vessels-accessories/)[

Hei-TORQUE Overhead Stirrers

Hei-TORQUE Overhead Stirrers

](https://www.radleys.com/range/hei-torque-overhead-stirrers/)[

Reactor-Ready

Reactor-Ready Lab Reactor

](https://www.radleys.com/range/reactor-ready-lab-reactor/)

View all products


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드 결제 (결제링크 문자+이메일 전송)
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0