Thermo Fisher Scientific AmpFLSTR NGM SElect Express Kit
단일 소스 시료의 빠르고 효율적인 STR 분석을 위한 포렌식용 Express 키트. ESS Loci와 SE33 포함으로 높은 식별력 제공. 직접 증폭 및 자동화 처리 지원. 45분 내 PCR 완료로 신속한 결과 도출. 두 가지 패키지(200/1000회 반응) 제공.
- 카탈로그번호
- 4472193
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific AmpFLSTR NGM SElect Express Kit
Applied Biosystems™ AmpFLSTR™ NGM SElect™ Express Kit
The AmpFℓSTR NGM SElect Express Kit enables extremely efficient analysis of single-source samples for laboratories utilizing the European Standard Set Loci (ESSL) together with the highly discriminating SE33 locus.
The kit employs a new master mix optimized for high-quality direct amplification of swab and paper substrates and supports rapid PCR cycling (<1 hr).
Key Features
- Supports rapid, direct amplification on treated/untreated paper and swab substrates with Prep-n-Go Buffer
- Enables high throughput and automated processing
- Reduces extraction, purification, and quantification costs
- New fast-capable enzyme allows amplification in ~45 minutes
- Maximizes first-pass success rate, reducing repeat amplifications
- Integrated solution for efficient single-source sample processing
- Enables sample-to-result workflow in approximately 2 hours
Data Quality Worth Sharing
Designed to deliver high discrimination and data quality for cross-border data sharing initiatives.
Meets ENFSI and EDNAP requirements and includes the expanded European Standard Set of Loci (ESSL).
Simultaneously amplifies 16 loci (D3S1358, vWA, D16S539, D2S1338, D8S1179, D21S11, D18S51, D19S433, TH01, FGA, Amelogenin, D10S1248, D22S1045, D2S441, D1S1656, D12S391) plus SE33 in the PET (red) dye channel.
Powerful Discrimination
Combines loci that generate one of the highest powers of discrimination among AmpFℓSTR kits.
Maximizes Concordance
Maintains identical primer sequences for core STR loci common to SGM Plus, Identifiler, and SEfiler Plus kits:
- Maximizes concordance with existing datasets
- Minimizes repeat analyses for non-concordant results
- Simplifies training and implementation
The SE33 locus primers were redesigned from SEfiler Plus to relocate the amplicon within the multiplex, maintaining concordance and performance.
Easy to Implement and Use
Designed for ease of implementation and high-quality results for both database and casework samples.
- Simplified reaction setup (enzyme included in master mix)
- Shortened cycling times (<1 hr)
- Compatible with manual and automated systems
- Available in 200 and 1000 reaction kits (larger bottles for automation)
For Forensic or Paternity Use Only.
Important Notice
Purchase of this product conveys a non-transferable license for forensic or paternity testing only.
Use for other applications (e.g., chimerism, cancer analysis, research, teaching) is not permitted.
Additional rights may be obtained from Promega Corp., 2800 Woods Hollow Rd., Madison, WI 53711 USA.
제품 사양
| 항목 | 내용 |
|---|---|
| 제품 라인 | NGM SElect |
| 제품 유형 | Express Kit |
| 용도(애플리케이션) | STR (Short Tandem Repeat) Analysis |
| 사용 장비 | GeneAmp 9700, Veriti Thermal Cycler |
| 라벨/염료 | FAM, LIZ, NED, PET, VIC |
| 수량 | 200 Reactions |
| 샘플 종류 | Blood Samples, Buccal Swab, Forensic Sample, Blood |
| 배송 조건 | Dry Ice |
| 타겟 Loci | D12S391, D22S1045, D19S433, vWA, D8S1179, D2S441, TH01, D18S51, D16S539, D3S1358, D2S1338, FGA, D1S1656, D10S1248, Amelogenin, SE33, D21S11 |
| Unit Size | Each |