CacheBy
Thermo Fisher Scientific HLA-DR Monoclonal Antibody (LN3), NovaFluor Blue 610-30S, eBioscience
원본

Thermo Fisher Scientific HLA-DR Monoclonal Antibody (LN3), NovaFluor Blue 610-30S, eBioscience

상품 한눈에 보기

사람 HLA-DR 항원을 인식하는 LN3 단클론 항체로, NovaFluor Blue 610-30S 형광체가 결합된 제품입니다. 유세포분석용으로 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 제공됩니다. 4°C 보관, 동결 금지.

카탈로그번호
H049T0xxxx (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 09:17
Thermo Fisher Scientific H049T03B05 HLA-DR Monoclonal Antibody (LN3), NovaFluor Blue 610-30S, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
676,200원VAT 포함 743,820원
Thermo Fisher Scientific H049T02B05 HLA-DR Monoclonal Antibody (LN3), NovaFluor Blue 610-30S, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
304,800원VAT 포함 335,280원

Thermo Fisher Scientific · Thermo Fisher Scientific HLA-DR Monoclonal Antibody (LN3), NovaFluor Blue 610-30S, eBioscience

Applications

  • Flow Cytometry (Flow): 5 µL (0.8 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Mouse / IgG2b, kappa
Class Monoclonal
Type Antibody
Clone LN3
Conjugate NovaFluor™ Blue 610-30S
Excitation / Emission Max 508 / 615 nm
Form Liquid
Concentration 0.8 µg/test
Purification Affinity chromatography
Storage Buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage Conditions 4°C, store in dark, DO NOT FREEZE
RRID AB_3098587 (AB_2925972)

Additional Available Formats

  • Unconjugated
  • Alexa Fluor 660
  • Alexa Fluor 700
  • Alexa Fluor Plus 488
  • Alexa Fluor Plus 647
  • APC
  • APC-eFluor 780
  • Biotin
  • Brilliant UV and Violet series
  • eFluor 450, 506
  • FITC
  • NovaFluor Blue series (510–800)
  • PE, PE-Cyanine5, PE-Cyanine7
  • PerCP-Cyanine5.5
  • Super Bright series
  • Custom conjugation available

Product Specific Information

Description:
The LN3 monoclonal antibody reacts with human MHC class II molecule HLA-DR, expressed on antigen-presenting cells (APCs) such as B cells, monocytes, macrophages, dendritic cells, and activated T cells. HLA-DR is a heterodimeric transmembrane protein composed of alpha and beta subunits and plays an essential role in peptide presentation to CD4⁺ T lymphocytes.

Each product includes one vial of NovaFluor conjugate and one vial of CellBlox Plus Blocking Buffer.

Applications Reported:
The LN3 antibody is reported for use in flow cytometric analysis.

Applications Tested:
Pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells.
Recommended usage: 5 µL (0.0075 µg) per test (100 µL final volume).
Applicable cell count: 10⁵–10⁸ cells/test.

Compatibility Notes:
NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability analysis.

Blocking Buffer Information:
This conjugate ships with CellBlox Plus Blocking Buffer (Cat. No. C001T06F01), which improves staining performance.
Use 5 µL per sample in antibody cocktails or single-color controls for optimal results.

Technology:
NovaFluor conjugates are based on Phiton™ technology, utilizing nucleic acid dye structures that enable engineered fluorescent signatures with optimized spillover and spread characteristics.

Excitation / Emission / Laser:
509 nm / 614 nm / 488 nm (Blue Laser)


Target Information

HLA-DR is a transmembrane glycoprotein composed of a 36 kDa alpha chain (DRA) and a 27 kDa beta chain (DRB).

  • The alpha chain gene (DRA) contains 5 exons encoding leader peptide, extracellular domains, transmembrane region, and cytoplasmic tail.
  • DRA acts as the sole alpha chain for DRB1, DRB3, DRB4, and DRB5.
  • DRB1 alleles determine peptide-binding specificity and are routinely typed for transplantation purposes.
  • HLA-DR is expressed mainly on APCs such as B lymphocytes, monocytes, macrophages, thymic epithelial cells, and activated T cells.
  • MHC class II molecules bind processed peptides and present them to T-helper cells, initiating immune responses.

HLA and MHC antibodies are critical in Immunopeptidomics, supporting neoantigen identification and characterization via LC-MS/MS.


For Research Use Only.
Not for use in diagnostic procedures.
Not for resale without express authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.