
Thermo Fisher Scientific TNF alpha Human ProcartaPlex Simplex Kit
인간 TNF alpha 단백질을 정량 분석하는 Simplex 키트로, Luminex xMAP 기술을 활용하여 다중 단백질 검출 가능. 소량의 시료(25–50 μL)로 빠른 결과 획득. 다른 Simplex 키트와 조합 가능하며, 면역학·종양학 연구에 적합.
- 카테고리
- Protein Kits
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific TNF alpha Human ProcartaPlex Simplex Kit
Invitrogen™ TNF alpha Human ProcartaPlex™ Simplex Kit
The Human TNF alpha Simplex ProcartaPlex Kit measures TNF alpha protein and is designed to be combinable with other Simplex kits, allowing creation of custom multiplex panels utilizing Luminex xMAP technology for protein detection and quantitation. When combining multiple Simplex kits (i.e., not using a pre-configured Multiplex Panel), only one buffer kit (sold separately) is required per assay plate regardless of plex size.
About ProcartaPlex Assays for the Luminex Platform
ProcartaPlex immunoassays are based on the sandwich ELISA principle, using two highly specific antibodies binding to different epitopes of one protein to quantitate multiple protein targets simultaneously using a Luminex instrument. These assays require as little as 25 μL of plasma or serum, or 50 μL of cell culture supernatant, and yield analyzed results within four hours.
- More results per sample — measure multiple protein targets simultaneously in a single 25–50 μL sample
- Well-established Luminex technology — highly referenced multiplexing platform for protein detection and quantitation
ProcartaPlex assays utilize Luminex xMAP (multianalyte profiling) technology for simultaneous detection and quantitation of up to 80 protein targets in a single 25–50 μL sample from plasma, serum, cell culture supernatants, and other bodily fluids.
The Luminex beads in the ProcartaPlex assay are internally dyed with precise proportions of red and infrared fluorophores to create spectrally unique signatures identifiable by Luminex xMAP detection systems (e.g., Luminex 200, FLEXMAP 3D, and MAGPIX). Similar to a sandwich ELISA, matched antibody pairs identify the target protein. In a multiplexed assay, each spectrally unique bead is labeled with antibodies specific for a single target protein, and bound proteins are identified with biotinylated antibodies and streptavidin–R-phycoerythrin (RPE). The conjugation of protein-specific antibodies to distinct beads allows analysis of multiple targets in a single well.
The key difference between a ProcartaPlex assay and ELISA is that the capture antibody in the ProcartaPlex assay is conjugated to a bead rather than adsorbed to a microplate well, meaning the reagents are free-floating in solution. For detection, the Luminex 200 instrument, for example, uses two lasers—one to distinguish bead spectral signatures and another to quantify RPE fluorescence, proportional to the protein amount present. ProcartaPlex multiplex assays can profile more target proteins using significantly less sample in the same time as a traditional ELISA.
ProcartaPlex multiplex panels are available in multiple formats across six species (human, mouse, rat, nonhuman primate, porcine, and canine).
For more information and a comprehensive list of protein targets, visit thermofisher.com/procartaplex.
제품 사양
| 항목 | 내용 |
|---|---|
| 제품 유형 | Simplex Kit |
| 수량 | 96 Tests |
| 종 | Human |
| Combinability | Combinable |
| 비드 유형 | TNF alpha [45] |
| 어세이 민감성 | As determined for Lot 1: 0.4 pg/mL |
| 어세이 범위 | As determined for Lot 1: 8.54 – 35,000 pg/mL |
| 형식 | Simplex Kit |
| 용도(장비) | Luminex™ Instruments |
| 유전자 | tumor necrosis factor |
| 유전자 별칭 | DIF-alpha, TNFA, TNFSF2, TNLG1F, TNF |
| 유전자 ID (Entrez) | 7124 |
| 유전자 기호 | TNF |
| 제품 라인 | ProcartaPlex™ |
| 단백질 | Tumor necrosis factor |
| 단백질 아형 | Cachectin, TNF-alpha |
| 샘플 종류 | Serum, Plasma, Cell Culture Supernatants |
| 샘플 부피 | Serum, Plasma: 25 μL; Cell Culture Supernatant: 50 μL |
| UniProt ID | P01375 |
| 배송 조건 | Wet Ice |
| Research Area | Immunology, Oncology, Neurobiology, Toxicology, Cytokines |
| Unit Size | Each |
Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.
