CacheBy
Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience
원본

Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience

상품 한눈에 보기

인간 CD3ε를 인식하는 UCHT1 단클론 항체로 NovaFluor Red 710 형광체 결합. 유세포 분석(Flow Cytometry)에 최적화되어 있으며, CellBlox Plus Blocking Buffer 포함. 637/713 nm에서 여기/방출, 적색 레이저(633–640 nm) 사용. 연구용으로만 사용 가능.

카탈로그번호
H002T0xxxx (2개 옵션)
판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 10:47
Thermo Fisher Scientific H002T03R04 CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience 100 tests pk판매 단위 pk ·
재고 확인 필요
777,400원VAT 포함 855,140원
Thermo Fisher Scientific H002T02R04 CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience 25 tests pk판매 단위 pk ·
재고 확인 필요
351,900원VAT 포함 387,090원

Thermo Fisher Scientific · Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience

Thermo Fisher Scientific CD3 Monoclonal Antibody (UCHT1), NovaFluor Red 710, eBioscience

Applications

  • Flow Cytometry (Flow)
    Tested Dilution: 5 µL (0.1 µg)/test

Product Specifications

항목 내용
Species Reactivity Human
Host / Isotype Mouse / IgG1, kappa
Class Monoclonal
Type Antibody
Clone UCHT1
Conjugate NovaFluor™ Red 710
Excitation / Emission Max 637 / 713 nm
Form Liquid
Concentration 4 µL/Test
Purification Affinity chromatography
Storage buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3097910 (AB_2896406)

Available Formats

  • Unconjugated
  • Alexa Fluor 532, 561, 660, 700
  • APC, APC-eFluor 780
  • Biotin
  • Brilliant UV 395–805
  • Brilliant Violet 421–786
  • eFluor 450, 506
  • FITC
  • Functional Grade
  • NovaFluor Blue, Red, UV, Violet, Yellow Series
  • PE, PE-Cyanine5, PE-Cyanine7, PE-eFluor 610
  • Super Bright 436–780
  • Custom conjugation available

Product Specific Information

The UCHT1 monoclonal antibody reacts with human CD3ε, a 20 kDa subunit of the TCR complex. The epsilon chain, along with CD3 gamma and delta, is essential for proper assembly, trafficking, and surface expression of the TCR complex. CD3 is expressed by thymocytes and mature T cells. Crosslinking of TCR via immobilized UCHT1 induces intracellular signaling leading to activation and proliferation.

Each product includes:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and validated for flow cytometry using normal human peripheral blood cells. Recommended use: 5 µL (0.1 µg)/test in a final 100 µL volume. Suitable for 10⁵–10⁸ cells/test.

Important Notes:

  • NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
  • Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability with NovaFluor dyes.
  • Use CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) for optimal staining. Add 5 µL per sample before combining with cells.
  • For single-color controls, use 5 µL buffer per 100 µL of cell sample (10³–10⁸ cells).

NovaFluor conjugates utilize Phiton technology based on nucleic acid dye structures engineered for optimized fluorescent signatures with minimized spillover and spread.

Excitation: 639 nm
Emission: 710 nm
Laser: 633–640 nm (Red)

Target Information

The CD3 complex transduces antigen-recognition signals into T-cell cytoplasm and regulates TCR surface expression. It consists of CD3γ, CD3δ, CD3ε, and CD3ζ subunits, structurally related members of the immunoglobulin superfamily encoded on chromosome 11. These subunits associate with intracellular signaling molecules through tyrosine-based motifs. CD3 is expressed on 68–82% of normal peripheral blood lymphocytes, 65–85% of thymocytes, and Purkinje cells, but not on B or NK cells. CD3 gene defects are associated with CD3 immunodeficiency.

For Research Use Only. Not for use in diagnostic procedures or resale.

제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.