CacheBy
Thermo Fisher Scientific MAFF Polyclonal Antibody
원본

Thermo Fisher Scientific MAFF Polyclonal Antibody

상품 한눈에 보기

MAFF 단백질을 인식하는 Thermo Fisher Scientific의 Rabbit Polyclonal Antibody. Western blot 및 IHC에 적합하며, 인간과 설치류 시료에 반응. 고순도 항원 친화 크로마토그래피 정제, 액상 형태로 제공. 연구용으로만 사용 가능.

판매단위
pk
카탈로그 보기

카탈로그

1개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 05. 오전 12:34
Thermo Fisher Scientific PA585462 MAFF Polyclonal Antibody 100 ul pk판매 단위 pk ·
재고 확인 필요
657,900원VAT 포함 723,690원

Thermo Fisher Scientific · Thermo Fisher Scientific MAFF Polyclonal Antibody

Applications

Western Blot (WB)

Immunohistochemistry (Paraffin) (IHC (P))

  • Tested Dilution: 1:100–1:1,000
  • Publications: None listed

Product Specifications

항목 내용
Species Reactivity Human, Rat
Published Species Bovine
Host / Isotype Rabbit / IgG
Class Polyclonal
Type Antibody
Immunogen Recombinant protein encompassing a sequence within the center region of human MAFF
Conjugate Unconjugated
Form Liquid
Concentration 1 mg/mL
Purification Antigen affinity chromatography
Storage Buffer PBS, pH 7, with 20% glycerol
Contains 0.01% thimerosal
Storage Conditions Store at 4°C short term. For long term storage, store at -20°C, avoiding freeze/thaw cycles.
Shipping Conditions Wet ice
RRID AB_2792602

Product Specific Information

  • Keep as concentrated solution.
  • Predicted reactivity: Mouse (97%), Rat (97%), Chicken (86%), Bovine (99%).
  • Positive Control: A431, A431 nuclear extract, rat skin, Huh7, HepG2, human MAFF-transfected 293T.
  • Store product as a concentrated solution. Centrifuge briefly prior to opening the vial.

Target Information

The MAFF gene encodes a basic leucine zipper (bZIP) transcription factor lacking a transactivation domain.
It binds the US-2 DNA element in the promoter of the oxytocin receptor (OTR) gene and likely heterodimerizes with other leucine zipper-containing proteins to enhance OTR gene expression during term pregnancy.
Homodimers may act as transcriptional repressors.
The gene may also be involved in cellular stress response.
Multiple transcript variants encoding two different isoforms have been identified.


WARNING: This product can expose you to chemicals including mercury, which is known to the State of California to cause birth defects or other reproductive harm.
For more information, visit www.P65Warnings.ca.gov.

For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.