Servicebio Electrophoresis System (Transfer)
상품 옵션 정보 | |||||||
---|---|---|---|---|---|---|---|
카탈로그 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
SVT-2 | Servicebio SVT-2 Electrophoresis Transfer System pk | 재고문의 | pk | 573,000원 | - | 630,300원 |
Product introduction
This product can be used with SVE-2 vertical electrophoresis. The electric field is used to transfer the proteins, nucleic acids, etc. in the gel after electrophoresis to the transfer membrane, and then the charged particles are further analyzed and studied by means of biochemical analysis.
Product Features
a. Double plate structure, can be used with SVE-2 electrophoresis tank.
b. The tank of the instrument is integrated injection molding with high transparency polycarbonate, it`s corrosion resistance, high transparency, consistent performance, etc..
c. The positive and negative electrodes of the transfer clip are distinct, with a handle function, which is easy to operate.
d. High transfer efficiency, transfer time is about 20-40min.
e. Strong structure can be synchronized with the ice bath cooling to avoid interference caused by overheating, so as to ensure reliable experimental results.
Product Specifications
SVE-2 | SVT-2 | |
Dimensions (L*W*H) mm | 185x108x125 | 185x108x125 |
Gel size/transfer size (mm) | Gel size 83x73 | Transfer size 70x90 |
Maximum volume of buffer (ml) | 500 | 500 |
Operation process
4.1 Preparation
Prepare 8 pieces of 7x9cm thin transfer membrane filter paper or 2 pieces of thick filter paper of the same specification in advance, and 1 piece of 7x9cm PVDF membrane (currently, the membrane with a pore size of 0.45μm is used for proteins greater than 20kda, and the membrane with a pore size of 0.2μm is used for proteins less than 20kda).
4.2 Activation
The PVDF membrane needs to be activated with methanol for 2 min before use.
4.3 Installation
According to the order of ‖ positive electrode (+) > sponge > filter paper > transfer film > gel > filter paper > sponge > negative electrode (-) ‖, place the transfer material in the transfer clip and remove the air bubbles. The red side is the positive direction, and the black side is the negative side. Place the transfer clip into the transfer core in the direction of red to red and black to black. The transfer core can hold two transfer clips at the same time.
* *
4.4 Power-on transfer
Connect the electrophoresis power supply, set the transfer conditions, and start transferring the membrane.
4. Product configuration list
S**erial number** | N**ame** | Q**uantity** |
1 | transfer clip | 2 sets |
2 | transfer core | 1 set |
3 | electrophoresis box | 1 set |
4 | Transfer sponge | 1 box |
5 | Transfer filter paper | 1 box |
Precautions
1. The main components of this series of products are fragile products. During packaging, transportation and use, be careful not to bump or drop the product, which may cause damage to the product and cause the product to fail to work normally.
2. Metal parts such as platinum wire and electrode column in this product should be paid attention to whether there are oxidation, breakage, loosening and other problems during use, cleaning and maintenance. Please replace and maintain them in time. The platinum wire is easily broken, so be careful when handling it.
3. After daily use, please wash it with deionized water in time, and place it in a dust-free place to dry for use.
Classification of related products
Products
Protein Biology Reagents | Consumables
Western Blotting
Transfer Consumables Instruments
Servicebio is one of the leading manufacturer in China providing FDA & CE approved lab supplies and lab services.
- Yu, J., et al.Quercetin Ameliorates Lipopolysaccharide-Induced Duodenal Inflammation through Modulating Autophagy, Programmed Cell Death and Intestinal Mucosal Barrier Function in Chicken Embryos.Animals (Basel)12,3524(2022).PMID 36552443IF 3
- PMID:36552443
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|