Thermo Fisher Scientific Phospha-Light SEAP Reporter Gene Assay System, 400 Assays

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
T1016-Thermo Fisher Scientific T1016 Phospha-Light SEAP Reporter Gene Assay System, 10,000 Assays 10,000 assays pk재고문의pk9,008,000-9,908,800
T1017-Thermo Fisher Scientific T1017 Phospha-Light SEAP Reporter Gene Assay System, 1200 Assays 1,200 assays pk재고문의pk1,620,000-1,782,000
T1015-Thermo Fisher Scientific T1015 Phospha-Light SEAP Reporter Gene Assay System, 400 Assays 400 assays pk재고문의pk737,000-810,700

Invitrogen™

Phospha-Light™ SEAP Reporter Gene Assay System

Phospha-Light™ assay system is a chemiluminescent reporter gene assay for the sensitive detection of secreted human placental alkaline phosphatase used자세히 알아보기

Phospha-Light™ assay system is a chemiluminescent reporter gene assay for the sensitive detection of secreted human placental alkaline phosphatase used as a reporter protein.

• Detection of a secreted reporter permits analysis without destroying valuable cells.
• Wide dynamic range of alkaline phosphatase assay lets the user measure enzyme level accurately from femtogram to nanogram range.
• Assay sensitivity is 100- to 1,000-fold better than with either the isotopic⁄non-isotopic assays for chloramphenicol acetyl transferase (CAT) or the colorimetric⁄fluorescent assays for b-galactosidase, providing greater sensitivity than competing assays.
• Highly sensitive assay with a wide dynamic range permits detection of high and low levels of reporter without the need to perform numerous sample dilutions.
• Non-radioactive reporter gene assay kit eliminates concerns over use of radioisotopes.
• Assay can be completed in about one hour, providing fast assay turnaround.

Monitor Expression Over Time
Phospha-Light™ assay system allows sensitive detection of secreted alkaline phosphatase (SEAP) reporter protein in cell culture media. The SEAP gene product is a truncated form of human placental alkaline phosphatase. A secreted reporter protein eliminates the need to prepare cell extracts. A population of cells can be monitored over time and remains intact for further experimentation.

Proprietary Reagents for Ultra-Sensitive Detection
Phospha-Light™ assay system is one of the easiest and fastest methods for optimizing transfection efficiency. A combination of proprietary reagents is the key to the highly sensitive detection achievable with the Phospha-Light™ assay. The system consists of CSPD™ high-performance alkaline phosphatase substrate, Emerald™ luminescence enhancer, and a unique buffer system designed to specifically inhibit non-placental endogenous alkaline phosphatase activity. The persistent glow of the chemiluminescent signal permits the use of luminometers without the need for injectors for measurement.

Applications
Phospha-Light™ reporter gene assay system has been used widely for reporter gene assays to measure gene expression in established cell lines and in transfected primary cells, including as a gene knockdown⁄RNA interference read-out. Phospha-Light reporter gene assay has been used for a wide variety of viral functional assays, including viral gene expression assays, viral replication, viral fusogenicity, virus neutralization and viral-mediated cell-cell fusion, and viral infectivity. Use of the SEAP reporter protein is very enabling for in vivo reporter gene assays, by assaying serum samples from transgenic, transfected or viral vector-infected animals. Phospha-Light reporter gene assay system has been used to measure SEAP levels in sera from transgenic or transfected whole animals, including mouse, rat, marmoset, monkey and pig sera, and in chicken egg allantoic fluid. The mouse SEAP protein (mSEAP) has recently been developed for improved SEAP protein stability in transgenic mice, and the Phospha-Light™ system has been used for sensitive detection of mSEAP. For these and additional references, please see our bibliography in the Literature⁄Resources section.

For Research Use Only. Not for use in diagnostics procedures.

사양

제품 유형Secreted Human Placental Alkaline Phosphatase Reporter Gene Assay System

검출 방법Chemiluminescence

용도(장비)Luminometer (Microplate)

어세이Reporter Assay

호환 셀Mammalian Cells

고처리량 호환성High-throughput Compatible

라벨 또는 염료Unconjugated

판독End Point

샘플 종류Cell Cultures

기질CSPD™

기질 유형AP (Alkaline Phosphatase) Substrate

기질 특성Chemical Substrate

타겟 효소Alkaline Phosphatase

제품라인NovaBright™, Phospha-Light™

용도(애플리케이션)Enzyme Assay

수량400 Assays

형태Liquid

Unit Size400 assays


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0