Thermo Fisher Scientific CD19 Monoclonal Antibody (HIB19), NovaFluor Blue 660-120S, eBioscience
인간 CD19 항원을 인식하는 HIB19 단클론 항체로, NovaFluor Blue 660-120S 형광체가 결합된 제품입니다. Flow Cytometry 분석에 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 사용 시 최적의 염색 성능을 제공합니다. 연구용으로만 사용 가능합니다.
- 카탈로그번호
- H004T0xxxxxx (2개 옵션)
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD19 Monoclonal Antibody (HIB19), NovaFluor Blue 660-120S, eBioscience
Thermo Fisher Scientific CD19 Monoclonal Antibody (HIB19), NovaFluor Blue 660-120S, eBioscience
Applications
- Flow Cytometry
Tested Dilution: 5 µL (1.0 µg)/test
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | HIB19 |
| Conjugate | NovaFluor™ Blue 660-120S |
| Excitation / Emission Max | 492 / 665 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage buffer | PBS, pH 7.2, with BSA |
| Contains | 0.09% sodium azide |
| Storage conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3097971 (AB_2896478) |
Additional Available Formats
- Unconjugated
- Alexa Fluor 488, 532, 561, 660, 700
- APC, APC-eFluor 780, Biotin
- Brilliant UV, Violet, Yellow series
- PE, PE-Cyanine5, PE-Cyanine7
- PerCP-Cyanine5.5, PerCP-eFluor 710
- Super Bright 436, 600, 645, 702, 780
- NovaFluor Blue, Red, Violet, Yellow series
- Functional Grade
- Request custom conjugation
Product Specific Information
The HIB19 monoclonal antibody reacts with human CD19, a 95 kDa transmembrane glycoprotein expressed by B cells during all stages of development except terminally differentiated plasma cells. Follicular dendritic cells also express CD19. CD19 forms a multimolecular complex with CD21, CD81, Leu13, and MHC class II, associating with BCR to induce tyrosine phosphorylation, calcium flux, and proliferation of B cells.
Each product contains:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis.
Applications Tested: Pre-titrated and tested by flow cytometric analysis of normal human peripheral blood cells. Use at 5 µL (1.0 µg) per test (100 µL final volume, 10⁵–10⁸ cells/test).
Note:
NovaFluor dyes are not compatible with DNA intercalating viability dyes such as propidium iodide, 7-AAD, and DAPI. Use Invitrogen LIVE/DEAD Fixable Dead Cell stains instead.
CellBlox Plus Blocking Buffer (Cat. No. C001T06F01):
Required for optimal staining with NovaFluor conjugates. Add 5 µL per sample to antibody cocktails before combining with cells. For single-color controls, use 5 µL per 100 µL of cell sample.
NovaFluor Technology:
Based on Phiton™ technology utilizing novel nucleic acid dye structures engineered for optimized fluorescent signatures, minimizing spillover and spread.
Excitation: 509 nm
Emission: 665 nm
Laser: 488 nm (Blue)
Target Information
CD19 is a member of the immunoglobulin superfamily with two Ig-like domains. It is expressed on 100% of peripheral B cells and some myeloid leukemia cells. CD19 acts as a signal-amplifying co-receptor for the B cell receptor (BCR) and regulates B cell proliferation and differentiation. Mutations lead to hypogammaglobulinemia, while overexpression causes B cell hyperactivity.
Usage
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.