CacheBy
Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience
원본

Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience

상품 한눈에 보기

Mouse VISTA 단백질을 인식하는 MIH64 단클론 항체로 NovaFluor Yellow 610 형광체가 결합된 제품입니다. Flow cytometry에 최적화되어 있으며, CellBlox Plus Blocking Buffer와 함께 제공됩니다. 비특이적 염색 최소화 및 높은 형광 안정성을 제공합니다.

판매단위
pk
카탈로그 보기

카탈로그

2개 옵션
회원가입 없이 바로 구매하세요
가입하지 않아도 비회원가로 구매하실 수 있습니다.
마지막 업데이트 2025. 08. 04. 오전 05:33
Thermo Fisher Scientific M035T03Y03-A VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience 100 ug pk판매 단위 pk ·
재고 확인 필요
1,059,700원VAT 포함 1,165,670원
Thermo Fisher Scientific M035T02Y03-A VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience 25 ug pk판매 단위 pk ·
재고 확인 필요
445,800원VAT 포함 490,380원

Thermo Fisher Scientific · Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience

Thermo Fisher Scientific VISTA Monoclonal Antibody (MIH64), NovaFluor Yellow 610, eBioscience

Applications

  • Flow Cytometry (Flow)

Tested Dilution: 0.4 µg/test
Publications: -


Product Specifications

항목 내용
Species Reactivity Mouse
Host / Isotype Rat / IgG2a, kappa
Class Monoclonal
Type Antibody
Clone MIH64
Conjugate NovaFluor™ Yellow 610
Excitation / Emission Max 551 / 614 nm
Form Liquid
Concentration 0.1 mg/mL
Purification Affinity chromatography
Storage buffer PBS, pH 7.2
Contains 0.09% sodium azide
Storage conditions 4°C, store in dark, DO NOT FREEZE!
RRID AB_3099101 (AB_2926226)

Additional Formats

  • APC
  • Brilliant UV 615
  • Brilliant UV 737
  • NovaFluor Blue 660-120S
  • NovaFluor Yellow 730
  • PE
  • PerCP-eFluor 710
  • Super Bright 436
  • Super Bright 600
  • Custom conjugation available

Product Specific Information

This MIH64 monoclonal antibody recognizes mouse VISTA (B7-H5, PD-H1).
It is validated for use in flow cytometry on both native and paraformaldehyde-fixed cells.

Each product contains:

  • 1 vial of NovaFluor conjugate
  • 1 vial of CellBlox Plus Blocking Buffer

Applications Reported: Flow cytometric analysis
Applications Tested: Flow cytometric analysis of mouse splenocytes (≤ 0.4 µg/test).
A test is defined as staining a 100 µL cell sample (10^5–10^8 cells/test).
Antibody titration is recommended for optimal performance.

Compatibility Notes:
NovaFluor dyes are incompatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assessment.

CellBlox Plus Blocking Buffer:
Updated formulation for optimal NovaFluor staining.
Add 5 µL per sample to antibody cocktails before combining with cells.
For single-color controls, use 5 µL per 100 µL cell sample (10^3–10^8 cells).

Technology:
NovaFluor conjugates utilize Phiton™ technology with engineered fluorescent signatures minimizing spillover and spread.
Excitation: 552 nm; Emission: 612 nm; Laser: 561 nm (Yellow).

Note:
NovaFluor Yellow 610 may non-specifically stain B cells in SJL mice.
No non-specific staining observed in BALB/c or C57BL/6 mice.


Target Information

VISTA (V-domain Ig containing suppressor of T-cell activation)
Also known as B7-H5 or PD-1H, encoded by the VSIR gene.

  • Expressed mainly on hematopoietic cells (myeloid > T cells).
  • Absent on B cells.
  • Suppresses CD4/CD8 T-cell proliferation and cytokine production.
  • Potential target for cancer immunotherapy.
  • Known ligands: CD28H, VSIG-3, VSIG-8.

For Research Use Only. Not for use in diagnostic procedures or resale without authorization.


제품 이미지

spectra

Thermo Fisher Scientific 상품 둘러보기

전체보기

문의

0

아직 등록된 문의가 없어요.