Thermo Fisher Scientific CD14 Monoclonal Antibody (61D3), NovaFluor Blue 585, eBioscience
인간 CD14 항원을 인식하는 Mouse IgG1 단클론 항체. NovaFluor Blue 585 형광체로 결합되어 유세포분석(Flow Cytometry)에 최적화. CellBlox Plus Blocking Buffer 포함, 높은 형광 안정성과 낮은 스필오버 특성. 연구용 전용 제품.
- 판매단위
- pk
카탈로그
2개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific CD14 Monoclonal Antibody (61D3), NovaFluor Blue 585, eBioscience
Thermo Fisher Scientific CD14 Monoclonal Antibody (61D3), NovaFluor Blue 585
Applications
- Flow Cytometry (Flow)
Tested dilution: 5 µL (0.6 µg)/test
View 1 publication
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Human |
| Published Species | Human |
| Host / Isotype | Mouse / IgG1, kappa |
| Class | Monoclonal |
| Type | Antibody |
| Clone | 61D3 |
| Conjugate | NovaFluor™ Blue 585 |
| Excitation / Emission Max | 493 / 586 nm |
| Form | Liquid |
| Concentration | 5 µL/Test |
| Purification | Affinity chromatography |
| Storage Buffer | PBS, pH 7.2 |
| Contains | 0.09% sodium azide |
| Storage Conditions | 4°C, store in dark, DO NOT FREEZE! |
| RRID | AB_3098224 (AB_2896673) |
Available Formats
- Unconjugated
- Alexa Fluor 488, 532, 660, 700
- APC, APC-eFluor 780
- Biotin
- Brilliant UV 395–805
- Brilliant Violet 421–786
- eFluor 450, 506
- FITC
- Functional Grade
- NovaFluor Blue 510, 555, 610-30S, 660-40S, 800
- NovaFluor Yellow 570, 660
- PE, PE-Cyanine5, PE-Cyanine7, PE-eFluor 610
- PerCP-Cyanine5.5, PerCP-eFluor 710
- Super Bright 436, 600, 645, 702, 780
- Request custom conjugation available
Product Specific Information
The 61D3 monoclonal antibody reacts with human CD14, a 53–55 kDa GPI-linked glycoprotein expressed on monocytes, interfollicular macrophages, and some dendritic cells. CD14 binds LPS-LBP complexes with high affinity on monocyte surfaces.
Each product includes:
- 1 vial of NovaFluor conjugate
- 1 vial of CellBlox Plus Blocking Buffer
Applications Reported: Flow cytometric analysis
Applications Tested: Pre-titrated and validated on normal human peripheral blood cells at 5 µL (0.6 µg)/test.
A test is defined as staining a cell sample (10⁵–10⁸ cells) in 100 µL final volume.
Important Notes:
- NovaFluor dyes are not compatible with DNA intercalating viability dyes (e.g., propidium iodide, 7-AAD, DAPI).
- Use Invitrogen LIVE/DEAD Fixable Dead Cell stains for viability assessment.
- CellBlox Plus Blocking Buffer (Cat. No. C001T06F01) must be used for optimal staining.
- Add 5 µL per sample before combining with cells.
- For single-color controls: 5 µL per 100 µL cell sample (10³–10⁸ cells).
Technology:
NovaFluor conjugates utilize Phiton™ technology, based on nucleic acid dye structures engineered for minimal spectral spillover and spread impact.
Excitation: 494 nm; Emission: 585 nm; Laser: 488 nm (Blue).
Target Information
CD14 is a 55 kDa GPI-anchored glycoprotein expressed on monocytes, macrophages, and neutrophils. It functions as a lipopolysaccharide receptor and exists in both membrane-bound and soluble forms. CD14 interacts with LPS-binding protein (LBP) and plays roles in immune recognition, inflammation, and apoptosis.
Associated diseases include Mycobacterium chelonae infection and Croup.
Alternative splicing produces multiple transcript variants of the same isoform.
For Research Use Only.