Thermo Fisher Scientific TaqMan Gene Expression Cells-to-CT Kit, 40 reactions

상품 옵션 정보
카탈로그 번호CAS 번호설명상태단위판매가할인가가격(VAT포함)수량 / 장바구니 / 찜
AM1729-Thermo Fisher Scientific AM1729 TaqMan Gene Expression Cells-to-CT Kit, 400 reactions Each pk재고문의pk10,282,000-11,310,200
AM1728-Thermo Fisher Scientific AM1728 TaqMan Gene Expression Cells-to-CT Kit, 100 reactions Each pk재고문의pk3,079,000-3,386,900
4399002-Thermo Fisher Scientific 4399002 TaqMan Gene Expression Cells-to-CT Kit, 40 reactions Each pk재고문의pk1,291,000-1,420,100

Invitrogen™

TaqMan™ Gene Expression Cells-to-CT™ Kit

Green features

The TaqMan™ Gene Expression Cells-to-CT™ Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification.자세히 알아보기

The TaqMan™ Gene Expression Cells-to-CT™ Kit makes it possible to perform expression analysis directly from cultured cells without RNA purification. This kit saves time and offers a simple workflow that is suitable for a few samples or can be easily incorporated into automated, high-throughput applications.

The TaqMan™ Gene Expression Cells-to-CT Kit is:
Complete—optimized workflow includes cell lysis reagents with gDNA removal, RT enzyme mix, buffer, and new TaqMan™ Gene Expression Master Mix
Fast—7-minute sample prep, including DNase treatment, at room temperature
Easy—lyse samples in a tube or directly in culture plates
Robust—perform gene expression analysis on 10–100,000 cells per sample; results equivalent to those from purified RNA
Efficient—contains sufficient reagents to generate 500 real-time PCR results from 100 starting samples

Featuring a unique method for lysing cultured cells while removing genomic DNA and preserving RNA integrity, the TaqMan™ Gene Expression Cells-to-CT™ Kit contains reverse transcription (RT) reagents for cDNA synthesis and TaqMan™ Gene Expression Master Mix for real-time PCR analysis. TaqMan™ primer⁄probe sets are sold separately.

Simple 7-minute sample preparation: part of a complete workflow
Whether you are using plates or tubes, the TaqMan™ Gene Expression Cells-to-CT™ Kit, which uses the simple 7-minute sample preparation procedure outlined (see figure), is designed for 10–100,000 cultured cells⁄sample. Cells are washed in PBS and lysed in solution for 5 minutes at room temperature; DNase treatment can be performed simultaneously. Lysis is terminated at room temperature by a 2-minute incubation with Stop Solution. The lysates are now ready for reverse transcription or storage at –20°C. Because samples can be processed directly in culture wells (96 or 384 wells), sample handling and the potential for sample loss or transfer error are minimized, facilitating rapid, high-throughput processing. Unlike old-fashioned, multi-step RNA isolation protocols, no heating, washing, or centrifugation steps are required. The kit greatly simplifies a laborious 30–60 minute process and reduces it to 7 minutes.

The TaqMan™ Gene Expression Cells-to-CT™ Kit workflow enables unsurpassed gene expression evaluation with any of the >700,000 TaqMan™ Gene Expression Assays. This kit has been extensively tested for specificity with a broad selection of TaqMan™ Gene Expression Assays and shows performance equivalent to that obtained with purified RNA (see figure).

Achieve unsurpassed performance and sensitivity
Unlike some competitor kits that limit the amount of lysate in the RT reaction to 5%, the TaqMan™ Gene Expression Cells-to-CT™ Kit can accommodate 45% of the total RT reaction volume as cell lysate. Additionally, cDNA can comprise up to 45% of the real-time PCR reaction volume. The large lysate volume in the optimized RT reaction, along with the large cDNA volume in the subsequent real-time PCR using the TaqMan™ Gene Expression Master Mix, lead to maximum sensitivity. The master mix amplifies the target precisely and accurately, enabling the detection of small quantities of target, such as transcripts expressed at low levels.

The ability to detect limited target quantities was tested by mixing a constant number of human cells with various numbers of mouse cells. The cell mixtures were prepared using the TaqMan™ Gene Expression Cells-to-CT™ and assayed for a mouse-specific and human-specific gene. Comparative data were generated in the same manner with RNA purified by traditional methodology. The data show that RNA from as few as 10 mouse cells was detectable in a background of RNA from 10,000 human cells (see figure). The ability of the TaqMan™ Gene Expression Cells-to-CT™ Kit to detect relative low abundance transcripts was equivalent to that of purified RNA; at low levels, it was superior.

Additionally, the performance of the TaqMan™ Gene Expression Cells-to-CT™ Kit was compared to competitor lysate kits and to purified RNA. Inputs of 100–100,000 cells⁄lysis reaction were examined. The sensitivity of the TaqMan™ Cells-to-CT™ Kit protocol was equivalent to that obtained with purified RNA, and it surpassed competitor lysates (see figure). Furthermore, the lack of inhibition at high cellular inputs and the low variation among technical replicates demonstrate the reliability of this approach for gene expression studies using cultured cells.

Proven performance, proven together
All components of the TaqMan™ Gene Expression Cells-to-CT™ Kit have been optimized for consistent and reliable performance. This removes the guesswork involved in assembling separate sample preparation, RT, and real-time PCR kits. And the TaqMan™ Gene Expression Cells-to-CT™ Kit has been validated with TaqMan™ Gene Expression Assays for added quality assurance.

Accessory product
The TaqMan™ Cells-to-CT™ Control Kit was designed for use with the TaqMan™ Gene Expression Cells-to-CT™ Kit. This kit contains an endogenous control (ACTB) to normalize for sample loading variability and an artifical XenoRNA™ control and corresponding TaqMan™ Gene Expression Assay to monitor the effects of PCR inhibition.

사양

검출 방법Primer-probe

형식Tube

GC-Rich PCR PerformanceHigh

PCR 방법2-step RT-qPCR

중합효소DNA Polymerase

반응 속도Standard

용도(장비)7000 System, 7300 System, 7500 System, 7900HT System, Applied Biosystems StepOnePlus™ Fast Real-Time PCR System, StepOne™, Standard Mode, StepOnePlus™, Standard Mode, QuantStudio 6 and 7 Pro systems, QuantStudio 7 Flex system, QuantStudio 3 and 5 systems, QuantStudio 12k Flex system, QuantStudio 6 Flex system

그린 기능Fewer resources used and less waste, Less hazardous

패시브 참조 염료ROX (Pre-mixed)

제품라인Ambion™, Cells-to-CT™, TaqMan™

제품 유형Gene Expression Cells-to-C Kit

순도 또는 품질 등급UP (Ultra Pure)

수량40 reactions

역전사 효소M-MLV

배송 조건Dry Ice

충분40 Reactions

반응 수40 Reactions

샘플 종류Cell

Unit SizeEach


배송/결제/교환/반품 안내

배송 정보

기본 배송비
  • - 배송비 3,850원 (부가세 포함)
  • - 10만원 이상 구매시 배송비 무료
  • - 도서산간 및 제주를 포함한 일부 지역 추가비용 발생
  • - 장비의 경우 추가 배송비 및 설치비가 청구 될 수 있습니다
교환/반품 배송비
  • - 상품 별로 상이
착불 배송비
  • - 착불 적용 상품에 개별 부과 (상품 별로 상이)
교환/반품 배송비
  • - 상품 별로 상이

결제 및 환불 안내

결제 방법
  • - 신용카드
  • - 가상계좌
  • - 연구비카드
  • - 세금계산서 (기업은행 033-502993-01-019)
  • - 세금계산서 (신한은행 100-032-703829)
  • - 상품 결제 후 최대 60일 이내 제공 완료
취소
  • - 취소 접수 후 3 ~ 5일 이내 환불 처리
반품
  • - 반품 접수 후 3 ~ 5일 이내 환불 처리
환급
  • - 회사는 회원이 구매신청한 상품 등이 품절 등의 사유로 인도 또는 제공할 수 없을 때에는 지체 없이 그 사유를 회원에게 통지하고,
      사전에 상품 등의 대금을 받은 경우에는 대금을 받은 날로부터 3영업일 이내에 환급하거나 환급에 필요한 조치를 취합니다.

교환 및 반품 접수

교환 및 반품 접수 기한
  • - 상품 수령일로부터 7일 이내
교환 및 반품 접수가 가능한 경우
  • - 제품의 하자는 없지만, 다른 상품으로 교환하거나 반품 원하는 경우
     (배송비 고객 부담)
  • - 상품자체 불량 및 하자에 의한 경우
  • - 상품 오배송에 의한 경우
교환 및 반품 접수가 불가능한 경우
  • - 상품 수령 후 7일을 초과한 경우
  • - 개별 포장 상품의 포장을 훼손한 경우
  • - 고객의 고의적인 귀책으로 상품가치가 훼손된 경우
  • - 주문제작을 통해서 제품을 생산하는 경우
  • - 주문 당시 재고가 없어서 해외를 통해 제품을 수입해서 구매하는 경우

교환 및 반품 신청

교환 절차
  • - 상품 불량/오배송/상품파손
  • - 전화(02-585-1342) 또는 info@cacheby.com에 상품교환 접수
반품 절차
  • - 반품할 품목을 확인 후 info@cacheby.com로 반품 신청 (수령 후 7일 이내 가능하며 이후 불가)
  • - 전달드린 주문번호와 함께 반품 상품을 포장
     (포장을 꼼꼼하게 해주셔야 반품 상품 손상에 따른 불이익이 없습니다.)
  • - 택배회사 방문 시 반품 상품 전달
     (택배사의 반송장은 상품 교환이 완료될 때까지 보관해주시기 바랍니다.)
  • - 회수된 제품 확인 후 하자없을시 배송비를 제외하고 환불 처리 진행
     (환불 처리 후 입금까지 최대 2주까지 소요될 수 있습니다.)

문의 0