Thermo Fisher Scientific Pierce Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL
1. 1.8K MWCO 폴리아크릴아마이드 수지를 사용한 단백질 탈염 및 버퍼 교환용 컬럼 2. 효소 분해 및 미생물 오염에 강한 안정적인 폴리아크릴아마이드 매트릭스 3. 단백질, 펩타이드 등 고분자 시료에서 염, 저분자 화합물 제거에 적합 4. pH 2~10 범위에서 안정적이며, 120°C에서 오토클레이브 가능 5. 5 mL 용량, 단일 사용 컬럼으로 간편한 중력 흐름 방식
✨AI 추천 연관 상품
AI가 분석한 이 상품과 연관된 추천 상품들을 확인해보세요
연관 상품을 찾고 있습니다...
Thermo Scientific™ Pierce™ Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL
Pierce™ 1.8K MWCO Polyacrylamide Desalting Columns are pre-packed with porous polyacrylamide beads and provide efficient buffer exchange and desalting of proteins and other macromolecular samples based on a molecular-weight cutoff (MWCO) of 1800.
Unlike other size-exclusion media, polyacrylamide resin is not subject to enzymatic degradation and does not serve as a nutrient for microbial growth. The resin is highly hydrophilic, minimizing undesirable binding interactions between resin and sample molecules. Contamination with low molecular weight sugars is not a concern when using polyacrylamide resin.
Oxidizing agents can be removed without damaging the support. The resin is susceptible to hydrolysis under extreme pH conditions; therefore, an operating pH range of 2–10 is recommended at room temperature. It can be autoclaved at pH 5.5–6.5 for 30 minutes at 120°C.
These columns use resin beads with a wet diameter of 45–90 μm and are ideal for separating peptides and small macromolecules (>1.8 kDa) from buffer salts and other low molecular weight compounds (<500 MW).
Features of Polyacrylamide Resin
- Stable in water, salt solutions, organic solvents, and acidic or alkaline conditions
- Excellent flow properties
- Heat-stable
Applications
- Removing salts from protein solutions
- Removing phenol from nucleic acid preparations
- Separating excess crosslinker from conjugate preparations
- Removing excess derivatizing agents from modified proteins
- Removing unreacted dye from fluorescent antibodies
- Removing free radiolabel from labeled proteins
- Exchanging one buffer for another
Principle of Operation
Gravity-flow resin filtration separates molecules based on size and ability to penetrate the stationary phase. The chromatographic matrix consists of small, uncharged porous particles packed into a column. Large molecules are excluded from the pores and elute first, while smaller molecules penetrate the pores and elute later with additional buffer volume.
Desalting and buffer exchange are among the most common applications of resin filtration chromatography.
Related Products
- Pierce™ Polyacrylamide Spin Desalting Columns, 7K MWCO, 0.7 mL
- Polyacrylamide Desalting Columns, 6K MWCO, 10 mL
제품 사양
| 항목 | 내용 |
|---|---|
| 설명 | Pierce™ Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL |
| 제품 유형 | Desalting Column |
| 형식 | Gravity Flow Column |
| 정제 타겟 | Buffer Exchange, Protein |
| 컬럼 유형 | Size-exclusion, Polyacrylamide Resin |
| MWCO | 1.8 kDa |
| 제품라인 | Pierce™ |
| 일회용 | Single-use |
| 수량 | 5 Columns |
| 부피(미터법) | 1.25 mL |
| Unit Size | Each |
🏷️Thermo Fisher Scientific 상품 둘러보기
동일 브랜드의 다른 상품들을 확인해보세요

Thermo Fisher Scientific
Thermo Fisher Scientific 1-Step ABTS Substrate Solution
195,500원

Thermo Fisher Scientific
Thermo Fisher Scientific Pierce Dextran Desalting Columns, 5K MWCO, 5 mL, 5 Columns
210,200원

Thermo Fisher Scientific
Thermo Fisher Scientific Pierce Polyacrylamide Desalting Columns, 1.8K MWCO, 5 mL
292,300원

Thermo Fisher Scientific
Thermo Fisher Scientific KIMTECH WIPER MEDIUM
90,100원

Thermo Fisher Scientific
Thermo Fisher Scientific KLEENGUARD BOOTS COVER 400
341,600원
배송/결제/교환/반품 안내
배송 정보
| 기본 배송비 |
| 교환/반품 배송비 |
|
|---|---|---|---|
| 착불 배송비 |
| ||
| 교환/반품 배송비 |
| ||
결제 및 환불 안내
| 결제수단 |
|
|---|---|
| 취소 |
|
| 반품 |
|
| 환급 |
|
교환 및 반품 접수
| 교환 및 반품 접수 기한 |
|
|---|---|
| 교환 및 반품 접수가 가능한 경우 |
|
| 교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
| 교환 절차 |
|
|---|---|
| 반품 절차 |
|