Thermo Fisher Scientific Dinitrophenyl-KLH Polyclonal Antibody, Alexa Fluor 488
Alexa Fluor 488로 결합된 Dinitrophenyl-KLH 폴리클로날 항체로, DNP-표지 분자 검출에 적합. WB, IHC, ICC, Flow Cytometry 등 다양한 응용 가능. 고순도 정제된 Rabbit IgG로 제조되어 신뢰성 높은 형광 검출 제공. 연구용으로만 사용.
- 카탈로그번호
- A11097
- 판매단위
- pk
카탈로그
1개 옵션 · 카탈로그 번호를 클릭하면 복사됩니다Thermo Fisher Scientific · Thermo Fisher Scientific Dinitrophenyl-KLH Polyclonal Antibody, Alexa Fluor 488
Applications and Tested Dilution
| Application | Tested Dilution | Publications |
|---|---|---|
| Western Blot (WB) | Assay-dependent | 3 publications |
| Immunohistochemistry (IHC) | Assay-dependent | 13 publications |
| Immunocytochemistry (ICC/IF) | Assay-dependent | 6 publications |
| Flow Cytometry (Flow) | - | 5 publications |
| Miscellaneous PubMed (Misc) | - | 1 publication |
Product Specifications
| 항목 | 내용 |
|---|---|
| Species Reactivity | Chemical |
| Published Species | Chemical |
| Host / Isotype | Rabbit / IgG |
| Class | Polyclonal |
| Type | Antibody |
| Immunogen | Dinitrophenyl-KLH |
| Conjugate | Alexa Fluor™ 488 |
| Excitation / Emission Max | 499 / 520 nm |
| Form | Liquid |
| Concentration | 2 mg/mL |
| Purification | Purified |
| Storage Buffer | PBS, pH 7.5 |
| Contains | 5 mM sodium azide |
| Storage Conditions | 4°C, store in dark |
| Shipping Conditions | Wet ice |
| RRID | AB_2534131 |
Product Specific Information
The anti-DNP-KLH antibody is supplied in 0.1 M sodium phosphate, 0.1 M sodium chloride, pH 7.5, containing 5 mM sodium azide. The degree of labeling is indicated on the product label. This antibody was raised in rabbit against DNP conjugated to keyhole limpet hemocyanin. The IgG fraction, which contains both anti-DNP and anti-KLH IgGs, was isolated from total serum and determined to be >95% pure by SDS-PAGE.
It is recommended to briefly centrifuge protein conjugate solutions before use and use only the supernatant to avoid aggregates that may cause nonspecific background staining. Appropriate antibody dilution should be determined empirically for each application.
Peak absorption and fluorescence emission wavelengths for Alexa Fluor™ 488 anti-DNP-KLH conjugate are 494 nm and 520 nm, respectively.
Because of their high affinity for the dinitrophenyl hapten (DNP), Invitrogen’s anti-DNP-KLH antibodies are sensitive probes for detecting DNP-labeled molecules. The fluorescent and biotinylated anti-DNP-KLH conjugates can serve as second-step reagents for signal amplification in protein and nucleic acid detection systems, including in situ hybridization studies employing DNP-modified DNA probes.
Anti-DNP antibody binds well to DAMP, an acidotropic reagent that penetrates cell membranes, enabling immunochemical localization of intracellular compartments with low pH. Additionally, anti-DNP-KLH antibodies may recognize compounds with a trinitrophenyl group, allowing isolation of cell-surface molecules of human melanoma cells labeled with trinitrobenzene sulfonic acid (TNBS).
Target Information
DNP-KLH antibodies are used for detecting DNP-labeled molecules. Fluorescent and biotinylated anti-DNP-KLH conjugates can serve as second-step reagents for signal amplification in protein and nucleic acid detection systems, including in situ hybridization studies employing DNP-modified DNA probes. Because anti-DNP antibody binds well to DAMP (D-1552), an acidotropic reagent that can penetrate cell membranes, anti-DNP-KLH antibodies can also be used with DAMP for immunochemical localization of intracellular compartments with low pH. DNP-KLH antibodies may recognize compounds with a trinitrophenyl group, allowing the isolation of cell-surface molecules of human melanoma cells that have been labeled with trinitrobenzene sulfonic acid (TNBS).
For Research Use Only. Not for use in diagnostic procedures. Not for resale without express authorization.
제품 이미지

Thermo Fisher Scientific 상품 둘러보기
전체보기문의
0개 · 배송·재고 문의는 실시간 상담이 빠릅니다아직 등록된 문의가 없어요.