Thermo Fisher Scientific TaqMan Cells-to-CT Express Kit, 40 reactions
상품 옵션 정보 | ||||||||
---|---|---|---|---|---|---|---|---|
카탈로그 번호 | CAS 번호 | 설명 | 상태 | 단위 | 판매가 | 할인가 | 가격(VAT포함) | 수량 / 장바구니 / 찜 |
A57985 | - | Thermo Fisher Scientific A57985 TaqMan Cells-to-CT Express Kit, 40 reactions Each pk | 재고문의 | pk | 0원 | - | 0원 | |
A57986 | - | Thermo Fisher Scientific A57986 TaqMan Cells-to-CT Express Kit, 100 reactions Each pk | 재고문의 | pk | 0원 | - | 0원 | |
A57987 | - | Thermo Fisher Scientific A57987 TaqMan Cells-to-CT Express Kit, 400 reactions Each pk | 재고문의 | pk | 0원 | - | 0원 | |
A57988 | - | Thermo Fisher Scientific A57988 TaqMan Cells-to-CT Express Kit, 2500 reactions Each pk | 재고문의 | pk | 0원 | - | 0원 |
Invitrogen™
TaqMan™ Cells-to-CT™ Express Kit
The TaqMan Cells-to-CT Express Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells자세히 알아보기
The TaqMan Cells-to-CT Express Kit is a complete cell lysate system designed for gene expression analysis directly from cultured cells without RNA purification. It enables RT-qPCR of the highest sensitivity and quickest workflow using just five components: Express Lysis Buffer, Express ezDNase, Express RT Master Mix, RT controls, and our best-in-class TaqMan Fast Advanced Master Mix. The TaqMan Cells-to-CT Express Kit provides the sensitivity you need in the fastest workflow available: RT-qPCR results for gene expression analysis in approximately 70 minutes.
Features of the TaqMan Cells-to-CT Express Kit include:
- Extraordinary ease and speed—96 samples ready for RT-qPCR in as little as 5 minutes
- No tedious RNA purification—no columns, heating, or centrifugation
- Verified workflows—complete set of reagents optimized to work efficiently right out of the box
- Environmentally friendly—the kit is REACH Compliant, has fewer components, and requires fewer pipetting steps reducing plastics costs
- Right sized kits for automation—available in 2500 reaction size that includes both lysis and RT components
Optimized chemistry with no need for stop solution
Gene expression analysis from direct cell lysis is made simple with our TaqMan Cells-to-CT Express Kit. With only one step for cell lysis and no need for the addition of a Stop Solution, our Express technology enables a rapid workflow with sensitive, accurate, and reproducible results. 10–100,000 cells are lysed using the Express Lysis Solution. The optional inclusion of ezDNase to the Express Lysis Solution enables removal of genomic DNA during cell lysis. Following a 5-minute incubation at room temperature, the lysate is used directly for reverse transcription using SuperScript IV VILO Master Mix. Once the RT reaction is complete, qPCR analysis is carried out using TaqMan Fast Advanced Master Mix and a TaqMan Gene Expression Assay.
Streamlined workflow allowing for rapid, accurate and sensitive results
RNA prepared using the TaqMan Cells-to-CT Express technology substantially expedites and streamlines gene expression analysis. Cell lysates exhibit sensitivity and specificity better than or equivalent to RNA extracted using traditional spin column isolation methods. The lysis procedure simultaneously prepares cell lysates for RT-qPCR and removes genomic DNA in only five minutes. The lysis step is simple to automate with robotic platforms for high-throughput processing of 96- or 384-well plates because it takes place entirely at room temperature. The procedure is also economical as there are only a few pipetting steps and, for cells grown in 96- or 384-well plates, no sample transfers. The high efficiency SuperScript IV VILO RT Master Mix transcribes even the most difficult (degraded and low abundant) RNA while reducing the typical reaction time by 10 minutes. Additionally, the TaqMan Cells-to-CT Express Kit is compatible with over 700,000 TaqMan Gene Expression Assays.
Maximize sensitivity of detection
Unlike some competitor kits that limit the amount of lysate in the RT reaction to 10%, the TaqMan Cells-to-CT Express Kit can accommodate 45% of the total RT reaction volume as cell lysate. Additionally, cDNA can comprise up to 45% of the real-time PCR reaction volume. The large lysate volume in the optimized RT reaction, along with the large cDNA volume in the subsequent real-time PCR using the TaqMan Fast Advanced Master Mix, lead to maximum sensitivity. The master mix amplifies the target precisely and accurately, enabling the detection of small quantities of target, such as transcripts expressed at low levels.
사양
검출 방법TaqMan
형태Liquid
형식Kit
GC-Rich PCR PerformanceHigh
PCR 방법2-step RT-qPCR
반응 속도5 min. (Fast)
그린 기능Less hazardous, less waste
고처리량 호환성Yes
키트 유형Direct Cell Lysis RT-qPCR
라벨 또는 염료ROX
수량40 reactions
유통 기한1 Year
배송 조건Frozen, Dry Ice
타겟cDNA
용도(애플리케이션)Gene Expression
분리 기술Direct cell lysis
반응 수40 Reactions
정제 타겟RNA
샘플 종류Mammalian Cells
시작 물질10-100,000 Cells
Unit SizeEach
배송/결제/교환/반품 안내
배송 정보
기본 배송비 |
| 교환/반품 배송비 |
|
---|---|---|---|
착불 배송비 |
| ||
교환/반품 배송비 |
|
결제 및 환불 안내
결제 방법 |
|
---|---|
취소 |
|
반품 |
|
환급 |
|
교환 및 반품 접수
교환 및 반품 접수 기한 |
|
---|---|
교환 및 반품 접수가 가능한 경우 |
|
교환 및 반품 접수가 불가능한 경우 |
|
교환 및 반품 신청
교환 절차 |
|
---|---|
반품 절차 |
|